Wood Screw Applications – WS series continued<br />
Fasteners<br />
Joining 2, 3, or 4 Ply LVL or PSL Members<br />
Installation Notes:<br />
• For 2 ply members, wood screws shall be installed with<br />
the screw heads in the loaded ply.<br />
• For 3 or 4 ply members, wood screws shall be installed in<br />
both outer plies.<br />
• Designer shall specify all wood screws locations.<br />
• Increase edge and end distances if wood splitting occurs.<br />
• Stagger all screws installed into the opposite face.<br />
• A minimum of 2 rows of screws shall be used for all<br />
members with H = 5 1/2˝ and larger.<br />
Dimensions (in)<br />
Maximum Allowable Uniform Loads<br />
Multiple<br />
Members<br />
<br />
that can be applied to either outside member 1,2,3,4,5,6<br />
LVL/PSL (S.G. = 0.46)<br />
Wood Screw Spacing<br />
<br />
<br />
<strong>USP</strong><br />
Installation 2 Rows 3 Rows<br />
2 Rows 3 Rows 2 Rows 3 Rows<br />
Stock No. Ref. No. Description (in) L SH T Figure 3,9,10 Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m<br />
1 1695 24.74 2545 37.14 1130 16.49 1695 24.74 850 12.40 1270 18.53<br />
WS35 SDS25312 3-1/2 3/4 2-1/2<br />
2 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />
4 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />
5 1130 16.49 1695 24.74 755 11.02 1130 16.49 565 8.25 850 12.40<br />
WS6 8 SDS25600 6 1-3/4 4<br />
3 1455 21.23 2185 31.89 970 14.16 1455 21.23 730 10.65 1090 15.91<br />
6 5100 74.43 7640 111.50 3400 49.62 5100 74.43 2550 37.21 3820 55.75<br />
1) Factored Resistance values determined in accordance with CSA O86-09 Clause 10.11.<br />
<br />
<br />
4) Except for Figure 6 installation, load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply.<br />
<br />
<br />
<br />
<br />
<br />
<br />
red font.<br />
L<br />
SH<br />
T<br />
Serrations<br />
1/4˝ Beveled reamer<br />
on 2 1/2˝ or longer<br />
Wood Screws<br />
Cut threads<br />
Self drilling point<br />
© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />
Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6<br />
WS35 installed<br />
in (2) 13/4˝ Ply<br />
WS35 installed<br />
in (3) 13/4˝ Ply<br />
WS6 installed<br />
in (4) 13/4˝ Ply<br />
WS35 installed<br />
in (1) 13/4˝,<br />
(1) 31/2˝ Ply<br />
WS35 installed<br />
in (2) 13/4˝,<br />
(1) 31/2˝ Ply<br />
WS6 installed<br />
in (2) 31/2˝ Ply<br />
Recommended Row Guidelines<br />
1˝ min. Recommended (Typ)<br />
Other Stagger patterns as approved by Engineer are acceptable<br />
1 1 /2˝<br />
min<br />
18<br />
H<br />
2 1 /2˝<br />
min<br />
2 1 /2˝<br />
min<br />
1 1 /2˝<br />
min<br />
Spacing<br />
4˝ min. – 24˝ max.<br />
Spacing<br />
4˝ min. – 24˝ max.<br />
1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />
4˝ min<br />
End of member<br />
continued on next page