Wood Screw Applications – WS series continued<br />

Fasteners<br />

Joining 2, 3, or 4 Ply LVL or PSL Members<br />

Installation Notes:<br />

• For 2 ply members, wood screws shall be installed with<br />

the screw heads in the loaded ply.<br />

• For 3 or 4 ply members, wood screws shall be installed in<br />

both outer plies.<br />

• Designer shall specify all wood screws locations.<br />

• Increase edge and end distances if wood splitting occurs.<br />

• Stagger all screws installed into the opposite face.<br />

• A minimum of 2 rows of screws shall be used for all<br />

members with H = 5 1/2˝ and larger.<br />

Dimensions (in)<br />

Maximum Allowable Uniform Loads<br />

Multiple<br />

Members<br />

<br />

that can be applied to either outside member 1,2,3,4,5,6<br />

LVL/PSL (S.G. = 0.46)<br />

Wood Screw Spacing<br />

<br />

<br />

<strong>USP</strong><br />

Installation 2 Rows 3 Rows<br />

2 Rows 3 Rows 2 Rows 3 Rows<br />

Stock No. Ref. No. Description (in) L SH T Figure 3,9,10 Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m<br />

1 1695 24.74 2545 37.14 1130 16.49 1695 24.74 850 12.40 1270 18.53<br />

WS35 SDS25312 3-1/2 3/4 2-1/2<br />

2 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />

4 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />

5 1130 16.49 1695 24.74 755 11.02 1130 16.49 565 8.25 850 12.40<br />

WS6 8 SDS25600 6 1-3/4 4<br />

3 1455 21.23 2185 31.89 970 14.16 1455 21.23 730 10.65 1090 15.91<br />

6 5100 74.43 7640 111.50 3400 49.62 5100 74.43 2550 37.21 3820 55.75<br />

1) Factored Resistance values determined in accordance with CSA O86-09 Clause 10.11.<br />

<br />

<br />

4) Except for Figure 6 installation, load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply.<br />

<br />

<br />

<br />

<br />

<br />

<br />

red font.<br />

L<br />

SH<br />

T<br />

Serrations<br />

1/4˝ Beveled reamer<br />

on 2 1/2˝ or longer<br />

Wood Screws<br />

Cut threads<br />

Self drilling point<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6<br />

WS35 installed<br />

in (2) 13/4˝ Ply<br />

WS35 installed<br />

in (3) 13/4˝ Ply<br />

WS6 installed<br />

in (4) 13/4˝ Ply<br />

WS35 installed<br />

in (1) 13/4˝,<br />

(1) 31/2˝ Ply<br />

WS35 installed<br />

in (2) 13/4˝,<br />

(1) 31/2˝ Ply<br />

WS6 installed<br />

in (2) 31/2˝ Ply<br />

Recommended Row Guidelines<br />

1˝ min. Recommended (Typ)<br />

Other Stagger patterns as approved by Engineer are acceptable<br />

1 1 /2˝<br />

min<br />

18<br />

H<br />

2 1 /2˝<br />

min<br />

2 1 /2˝<br />

min<br />

1 1 /2˝<br />

min<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

4˝ min<br />

End of member<br />