<strong>100</strong> BBL SINGLE COMPARTMENT<br />

2-PHASE SURGE TANK<br />

H2S or STANDARD SERVICE<br />

September 2006<br />

Operating data's<br />

Vessel equipment<br />

Volume <strong>100</strong> <strong>bbl</strong> (16 M3) 02 x 4" Nozzle for LSH & LSL<br />

No. of <strong>compartment</strong> One 02 x Oil Level Gauge with graduated scale<br />

Sour gas service Yes (as per MR01-75) 02 x Pressure Safety Valve (50, <strong>100</strong> or 150 PSI as per version)<br />

Instrument supply Gas from separator or rig air if sour gas 01 x Temperature Indicator 0-<strong>100</strong>°C c/w thermowell<br />

01 x Pressure Indicator (0-60, 0-160 or 0-250 PSI as per version)<br />

Design data's Version 1 Version 2 Version 3 01 x Inlet jet breaker<br />

Design pressure 50 PSI <strong>100</strong> PSI 150 PSI 01 x Gas outlet demister<br />

Design temperature 80°C 80°C 80°C 01 x Oil outlet vortex breaker<br />

Code of construction ASME VIII Division 1 / ANSI B31-3 01 x 18" manway<br />

01 x 1/2" vent ball valve<br />

External connection<br />

01 x 2" drain ball valve<br />

Oil inlet 3" Weco fig. 602 F 01 x 2" blind flange (vessel drain in horizontal position)<br />

Oil / Drain outlet 3" Weco fig. 602 M<br />

Gas outlet 3" Weco fig. 602 M Inlet line equipment<br />

Relief gas outlet 4" Weco fig. 602 M 01 x 3" by-pass ball valve to oil outlet<br />

Air instrument supply 1/2" Quick coupling 01 x 3" inlet ball valve<br />

LSL signal 1/4" Quick coupling 01 x Pressure Indicator (0-60, 0-160 or 0-250 PSI as per version)<br />

LSH signal<br />

1/4" Quick coupling<br />

Oil outlet equipment<br />

Dimensions & Weight (horizontal position)<br />

01 x 3" ball valve<br />

Length 7450 mm (293.3 ") 01 x 1/2" drain ball valve<br />

Width 2500 mm (98.4 ") 01 x sampling point 1/4" c/w 1 valve 1/4"<br />

Height 2750 mm (108.3 ")<br />

Weight<br />

12800 Kg (28260 lbs) / 13600 Kg (30000 lbs) EmptyGas outlet equipment<br />

01 x Pressure Controller (0-<strong>100</strong>, 0-250 PSI as per version)<br />

Miscellaneous equipment 01 x 2" PCV with 3/15 PSI actuator (Cv Max 59.7)<br />

Removable crash frame with roof plate<br />

01 x 2" ball valve<br />

20 PSI air/gas instrument system c/w scrubber, regulators & 1/4" tubing 01 x 1/2" vent ball valve<br />

01 x Set of nozzles 1/2"NPT for Data Aquisition System 01 x sampling point 1/4" c/w 2 valves 1/4"<br />

MAIN COMPONENT BRAND<br />

QUALITY<br />

Gas PCV & PC EMERSON FISHER <strong>100</strong>% radigraphy on vessel & 20% on process pipework<br />

LSH & LSL FMC-INVALCO 10% hardness test<br />

Ball Valves AOP <strong>100</strong>% MPI on lifting lugs and primary structure<br />

Options<br />

Hydrostatic Pressure Test as per code & Leak Test<br />

Gas Flow Orifice Fitting DANIEL equivalent / CANALTA <strong>100</strong>% traceabilty on vessel and pipes<br />

Gas Flow Recorder BARTON Instrument calibration reports & certificate of compliance<br />

Oil Automatic Flow Valve FMC-INVALCO<br />

Quality and Operating & Maintenance books<br />

OPTIONS<br />

Standard service equipment<br />

LSH/LSH pneumatic horn c/w check valves<br />

Automatic pneumatic control system c/w <strong>surge</strong> pulse counter, automatic inlet and oil outlet flow valves<br />

02 x 4" Nozzle c/w blind flange (for LSHH & LSLL option)<br />

01 x LSHH & 01 x LSLL (to be specified pneumatic or electric signal)<br />

4" Gas outlet line c/w 3" PCV, 3" ball valve and 4" Weco 602 at skid edge<br />

Gas metering orifice fitting and 3-pen recorder to gas outlet nominal size (DP cell range to be specified)<br />

Set of T, P & DP transmitters for Data Aquisition System (24Vdc)<br />

Set of cable and junction boxes for Data Aquisition System (24Vdc)<br />

Other PCV trim size or Cv Max on customer process requerement<br />

Other main component brand on customer request<br />

EN-12079 / DNV 2.7.1 crash frame / skid<br />

ASME U-stamp<br />

Full material traceability on wetted parts<br />

Load Test on skid and frame<br />

Fluid Control Europe (<strong>FCE</strong>)<br />

786 rue George Sand - ZI Molina la Chazotte - 42350 La Talaudière (France)<br />

Tel. +33 (0)4 77 48 13 13 - Fax +33 (0)4 77 33 01 30 - e-mail fce@fce.fr - web site www.fce.fr


<strong>100</strong> BBL SINGLE COMPARTMENT<br />

2-PHASE SURGE TANK<br />

H2S or STANDARD SERVICE<br />

September 2006<br />

2500 2750<br />

OPTIONAL<br />

LSHH<br />

LSH<br />

7450<br />

OD 2<strong>100</strong><br />

OIL / DRAIN OUTLET<br />

Weco 3'' 602 male<br />

OIL INLET<br />

Weco 3'' 602 femelle<br />

RELIEF GAS OUTLET<br />

Weco 4'' 602 male<br />

GAS OUTLET<br />

Weco 3'' 602 male<br />

(or 4" option)<br />

5160 TL/TL<br />

4663 (50 & <strong>100</strong> PSI) or 4699 (150 PSI) LSL/LSH for <strong>100</strong> <strong>bbl</strong><br />

T I<br />

P I<br />

LSL<br />

LSLL<br />

PNEUMATIC<br />

CONTROL<br />

PANEL<br />

1<strong>100</strong><br />

OPTIONAL<br />

Fluid Control Europe (<strong>FCE</strong>)<br />

786 rue George Sand - ZI Molina la Chazotte - 42350 La Talaudière (France)<br />

Tel. +33 (0)4 77 48 13 13 - Fax +33 (0)4 77 33 01 30 - e-mail fce@fce.fr - web site www.fce.fr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!