March 2009<br />

8.5.4 Shutdown Procedure<br />

1. Recover diver to bell <strong>and</strong> carry out post dive check off list.<br />

2. Switch off gas booster.<br />

3. Shut off O 2 <strong>and</strong> HeO 2 make up gas on control console.<br />

4. Turn off control console power.<br />

5. Shut off cooling water supplies to Booster <strong>and</strong> Reprocessing Unit.<br />

8.5.5 To change Soda lime<br />

1. Close inlet to canister.<br />

2. Close outlet from canister.<br />

3. Open drain valve at base.<br />

4. Unscrew top cap by h<strong>and</strong> when canister is fully vented.<br />

5. Place cap in box provided.<br />

6. Remove canister using h<strong>and</strong>le.<br />

7. Remove h<strong>and</strong>le <strong>and</strong> top gauze, <strong>and</strong> empty contents.<br />

8. Set empty canister in filling st<strong>and</strong>.<br />

9. Fill half full with soda lime.<br />

10. Add only one cupful of Purafil at 2/3 full.<br />

11. Fill to two thirds full with soda lime.<br />

12. Add one cupful of Purafil.<br />

13. Fill to top with Soda lime.<br />

14. Replace h<strong>and</strong>le <strong>and</strong> top lid.<br />

15. Lower inner canister slowly into outer canister.<br />

16. Replace top cap. It is O-ring sealed <strong>and</strong> seals when finger tight.<br />

17. Close drain valve at base.<br />

18. Open INLET valve on the LEFT SLOWLY.<br />

19. Open OUTLET valve on the RIGHT SLOWLY.<br />

20. Write hour meter reading of canister change on the control console in diver<br />

control.<br />

8.5.6 Changing Depth<br />

The make-up panel is provided to allow the oxygen content of the breathing gas to be<br />

altered rapidly to a new diving depth. To increase the oxygen content in the system,<br />

the following procedure should be followed.<br />