8.3.1 Start up Procedure<br />
1. Change Soda lime canisters as described in Section 8.5.5 <strong>and</strong> note time of canister<br />
change on Control Console panel.<br />
2. Ensure that all shut off valves in the system are open <strong>and</strong> one Soda lime canister<br />
is on line.<br />
3. Check booster oil level <strong>and</strong> top up with recommended lubricant if necessary.<br />
4. Check water level in booster header tank, top up with glycol water mix if<br />
necessary.<br />
5. Turn on seawater cooling supply booster.<br />
6. Turn on cooling supply to Reprocessing Unit.<br />
7. Set Control Console BPR loader, O 2 regulator <strong>and</strong> make-up regulator for the<br />
proposed diving depth according to Section 8.6.<br />
8. Crack the exhaust cross-connect valve <strong>and</strong> allow the exhaust umbilical pressure<br />
to rise to the correct value for the proposed dive, then close valve. This is the BPR<br />
loader pressure specified in Section 8.6.<br />
9. Ensuring that both stop/lock buttons are pulled out, switch on main isolator on<br />
booster starter panel. (Fault lights will illuminate).<br />
10. Press reset button on booster starter panel. (fault lights will go out).<br />
11. Select local or remote operation.<br />
12. Start booster from the indicated station.<br />
13. Check booster oil pressure. If gauge does not reach 50 psi (3.4 bar) within 30<br />
seconds, stop machine <strong>and</strong> investigate cause. (with excessively low oil pressure the<br />
booster will stop automatically due to pressure switches in the control circuit).<br />
14. Check gas quality by allowing gas to flow from the Reprocessing Unit sample<br />
regulator through the O 2 <strong>and</strong> CO 2 analysers in dive control.<br />
15. The unit is now ready to supply reclaimed gas to the diver.<br />
16. The gas booster will circulate gas around itself until such time as a diver starts<br />
breathing on recovery at which time the booster will automatically adjust to meet the<br />
diver’s breathing requirements.<br />
17. Initiate pre dive check off Bell Equipment <strong>and</strong> diver equipment (see bell check off<br />
lists in the following pages).<br />