March 2009<br />

When performing necessary corrective action in the following operations, refer to<br />

“Servicing” <strong>and</strong> “Repair” sections for the necessary procedure.<br />

Fault<br />

The regulated pressure continues to increase<br />

after lock-up <strong>and</strong> without change in Control<br />

Knob position.<br />

Continues leaking through Bonnet with outlet<br />

pressure on the Regulator.<br />

Regulated pressure drops off sharply when<br />

flow is within Regulator capabilities.<br />

Possible Cause<br />

1. Valve Seat (33) needs replacement.<br />

2. Sensor assembly needs cleaning <strong>and</strong> Seal<br />

replacement.<br />

1. Vent Valve needs adjustment.<br />

2. Vent valve seat (8) needs replacement.<br />

3. Sensor O-ring (4) worn <strong>and</strong> leaking.<br />

1. Check inlet Filter (37) <strong>and</strong> clean if necessary.<br />

2. Main Valve Seat (33) needs replacement.<br />