March 09<br />

7. The HeO 2 outlet gauge – indicates the pressure available to the volume tank. The<br />

reading on this gauge is the minimum volume tank pressure desired.<br />

8. The make-up gas flow light – indicates yellow when make-up gas is flowing into the<br />

volume tank.<br />

9. The make-up gas no flow light – indicates green when there is no flow through the<br />

make-up gas section.<br />

6.5.2 Thus, make-up oxygen is available from the oxygen regulator on the oxygen panel.<br />

Oxygen flows through a flow restrictor <strong>and</strong> check valve from the oxygen panel to the inlet<br />

receiver of the Reprossesing Unit.<br />

WARNING<br />

OXYGEN MAKE-UP SHOULD NEVER BE CARRIED OUT WHILE DIVING IS IN<br />

PROGRESS. THE SUPPLY-EXHAUST CROSS CONNECT SHOULD BE OPEN, AND<br />

THE BOOSTER RUNNING TO PROVIDE CIRCULATION AND MIXING THROUGH THE<br />

SYSTEM (SEE SECTION 8.3.4).<br />

6.6 Control Panel Maintenance<br />

6.6.1 Maintenance Schedule<br />

The routine maintenance required on the control panel is:<br />

Every 6 Months<br />

Check calibration of all gauges.<br />

Every Year (or as required)<br />

Dismantle <strong>and</strong> service regulators (see Sections 6.5.2).<br />

6.6.2 BPR Loader Regulator <strong>and</strong> O 2 Regulator – Maintenance <strong>and</strong> Repair<br />

Refer to: BPR Loader Regulator Drawing No. 81321 Page 6.18 O 2 Regulator Drawing<br />

No. 81320 Page 6.17<br />

WARNING<br />

IT IS ESSENTIAL THAT REGULATORS AND ASSOCIATED FITTINGS, PIPES ECT.<br />

ARE KEPT FREE OF HYDROCARBONS SUCH AS GREASES OR OIL DURING<br />

ASSEMBLY. THE ONLY LUBRICANTS WHICH MAY BE USED ARE CHRISTOLUBE<br />

MCG 111 OR OTHER SUITABLE NON HYDROCARBON GREASE. FOLLOWING<br />

MAINTENANCE, IT IS DESIRABLE TO OXYGEN CLEAN ALL REGULATORS.<br />

6.6.3 Recommended Tools<br />

OM002 Rev 5 Page 64 of 168 Chap 6