March 2009<br />

range of trace contaminants. These contaminants could originate from the diver himself or from<br />

off gassing from the umbilical.<br />

5.3.4 Purafil is effective in removing:<br />

Mercaptans, amines <strong>and</strong> ketones (responsible for many common odours);<br />

Ammonia;<br />

Hydrogen sulphide;<br />

Sulphur dioxide;<br />

Carbon monoxide (trace quantities only);<br />

5.3.5 This degree of scrubbing has been found satisfactory in normal diving applications. For<br />

other applications, particularly the recovery of the welder diver gas, consult Divex for<br />

recommended scrubbing systems.<br />

5.4 Reprocessing Unit – Routine Maintenance<br />

Maintenance Schedule<br />

NOTE<br />

All routine maintenance is based on actual running time as indicated on the hour meter in the<br />

control console.<br />

Every 4 Hours<br />

Next Due________Hrs.<br />

DRAIN ALL REPROCESSING UNIT FILTERS. F2 SHOULD CONTAIN LESS THAN A<br />

TABLESPOON OF WATER. F1 <strong>and</strong> F3 should contain about a cup of condensate.<br />

Every 8 Hours<br />

Next Due________Hrs.<br />

CHANGE CO 2 SCRUBBER after 8 man hours of use i.e. one diver one scrubber 8 hours or<br />

two divers two scrubbers 8 hours.<br />

CAUTION: CO 2 levels should be continuously monitored.<br />

Every 40 Hours<br />

Next Due________Hrs.<br />

CHECK ALL PROCESSING UNIT DRAIN VALVES, Filters F1 – F2 F3, Receivers R1-R2,<br />

Scrubbers S1-S2 <strong>and</strong> Float valve.<br />

Every 500 Hours<br />

Next Due________Hrs.<br />

REPLACE CO 2 SCRUBBER FILTER PADS on top <strong>and</strong> bottom of scrubber canisters.<br />

Chap 5 Page 47 of 168 OM002 Rev 5