5.3 Outlet Section<br />
Fig 2<br />
Outlet Section<br />
Scrubbers<br />
5.3.1 The outlet section consists of the following components:<br />
1. Scrubber inlet valves – provide manual shut-off of the scrubber unit.<br />
2. Scrubber/filter vent value – provides manual venting of the scrubber or filter prior to<br />
changing.<br />
3. Scrubber outlet valve – provides manual shut-off of the scrubber outlet.<br />
4. Scrubber assembly – removes CO 2 <strong>and</strong> odours by passing the gas through a bed of<br />
soda lime <strong>and</strong> Purafil.<br />
5. Heat exchanger – cools the exhaust gas to condense water vapour.<br />
6. Cooling water inlet valve – provides manual shut-off of cooling water to the heat<br />
exchanger.<br />
7. Filter F3 – 1 micron coalescing filter which collects moisture condensed in the heat<br />
exchanger.<br />
8. Diver supply pressure gauge – indicates the pressure of gas leaving the topside<br />
unit.<br />
9. Sample regulator shut-off valve – isolates sample regulator.<br />
10.Sample regulator – provides gas to analysers at 2 psi.<br />
11.The diver supply valve – provides manual shut-off of the gas supply from the<br />
Reprocessing Unit.<br />
5.3.2 The following describes the main components in more detail.<br />
5.3.3 The scrubber units consist of a deep bed of soda lime <strong>and</strong> Purafil. Soda lime is a<br />
widely used absorbent for carbon dioxide. Purafil is effective in removing odours <strong>and</strong> a wide<br />
OM002 Rev 5 Page 46 of 168 Chap 5