5.3 Outlet Section<br />

Fig 2<br />

Outlet Section<br />

Scrubbers<br />

5.3.1 The outlet section consists of the following components:<br />

1. Scrubber inlet valves – provide manual shut-off of the scrubber unit.<br />

2. Scrubber/filter vent value – provides manual venting of the scrubber or filter prior to<br />

changing.<br />

3. Scrubber outlet valve – provides manual shut-off of the scrubber outlet.<br />

4. Scrubber assembly – removes CO 2 <strong>and</strong> odours by passing the gas through a bed of<br />

soda lime <strong>and</strong> Purafil.<br />

5. Heat exchanger – cools the exhaust gas to condense water vapour.<br />

6. Cooling water inlet valve – provides manual shut-off of cooling water to the heat<br />

exchanger.<br />

7. Filter F3 – 1 micron coalescing filter which collects moisture condensed in the heat<br />

exchanger.<br />

8. Diver supply pressure gauge – indicates the pressure of gas leaving the topside<br />

unit.<br />

9. Sample regulator shut-off valve – isolates sample regulator.<br />

10.Sample regulator – provides gas to analysers at 2 psi.<br />

11.The diver supply valve – provides manual shut-off of the gas supply from the<br />

Reprocessing Unit.<br />

5.3.2 The following describes the main components in more detail.<br />

5.3.3 The scrubber units consist of a deep bed of soda lime <strong>and</strong> Purafil. Soda lime is a<br />

widely used absorbent for carbon dioxide. Purafil is effective in removing odours <strong>and</strong> a wide<br />

OM002 Rev 5 Page 46 of 168 Chap 5