Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
March 09<br />
5.2 Inlet Section<br />
Fig 1 Inlet Section<br />
1. Exhaust hose ball valve – isolates the system from the exhaust umbilical.<br />
2. Moisture separator F1 – removes liquid <strong>and</strong> solid particles down to 1 micron.<br />
3. Exhaust hose pressure gauge – monitors pressure in the return umbilical.<br />
4. Float valve – closes if water enters, preventing contamination of the Reprocessing<br />
Unit.<br />
5. Drain valve – provided on moisture separator <strong>and</strong> float valve.<br />
6. Back pressure regulator – controls the pressure in the main umbilical, eliminating<br />
any possibility of umbilical collapse.<br />
7. BPR loader gauge – indicates the reference pressure applied to the backpressure<br />
regulator.<br />
8. Oxygen injection – supplies an oxygen bleed from the control panel entering the<br />
system via a check valve prior to gas entering the first receiver.<br />
9. Receiver 1 – prevents exhaust side pulsation resulting from compressor operation<br />
<strong>and</strong> allows O 2 /helium mixing to take place.<br />
10.Relief valve – provides overpressure protection. It is set to lift at 1100 psi.<br />
11.Receiver 2 – as receiver 1.<br />
12.Flow switch – detects flow through the unit, indicating at the control panel when the<br />
flow stops <strong>and</strong> controls oxygen make up.<br />
13.Filter F2 – removes liquid <strong>and</strong> solid particles down to.01 micron.<br />
5.2.1 The function of the main components is considered in more detail in the following.<br />
OM002 Rev 5 Page 44 of 168 Chap 5