March 2009<br />

CHAPTER 5<br />

REPROCESSING UNIT<br />

CONTENTS<br />

Page<br />

General Description..................................................................................................................... 43<br />

Inlet Section................................................................................................................................. 44<br />

Outlet Section .............................................................................................................................. 46<br />

Reprocessing Unit – Routine Maintenance ................................................................................. 47<br />

List if Figures<br />

1 INLET SECTION..................................................................................................................................... 44<br />

2 OUTLET SECTION................................................................................................................................. 46<br />

3 LONG FILTER HOUSING ASSEMBLY (1500 PSI)................................................................................ 48<br />

4 CANISTER ASSEMBLY ......................................................................................................................... 49<br />

5 SCRUBBER HOUSING ASSEMBLY (1500 PSI).................................................................................... 50<br />

6 BACK PRESSURE REGULATOR ASSEMBLY ..................................................................................... 51<br />

7 FLOAT/CHECK VALVE ASSEMBLY...................................................................................................... 52<br />

8 RECEIVER ADAPTER ASSEMBLY 1 .................................................................................................... 53<br />

9 RECEIVER ADAPTER ASSEMBLY 2 .................................................................................................... 54<br />

10 FLOW SWITCH ASSEMBLY.................................................................................................................. 55<br />

11 SHUTOFF VALVE 1/4” NPT MALE ........................................................................................................ 56<br />

12 PRESSURE REGULATOR..................................................................................................................... 57<br />

5.1 General Description<br />

5.1.1 The function of the Reprocessing Unit is to add oxygen to restore the gas mixture then<br />

scrub the recovered gas to remove CO 2 <strong>and</strong> other contaminants. Its operation can be broken<br />

down into two sections.<br />

5.1.2 The Inlet Section consists of a moisture separator <strong>and</strong> float valve to prevent water<br />

being passed into the reprocessing unit, an oxygen injection point <strong>and</strong> two receivers which<br />

primarily smooth out fluctuations in the flow to the Electrical Gas Booster.<br />

5.1.3 The Outlet Section Gas is discharged to this section from the Electric Gas Booster<br />

outlet. It consists of further filtration to remove water particles <strong>and</strong> any other solid material.<br />

Chemical scrubbing is also employed to remove carbon dioxide <strong>and</strong> other trace contaminants.<br />

5.1.4 The operation <strong>and</strong> layout of each of these sections is described in the following.<br />