Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
March 2009<br />
4.8 Water Trap Inspection <strong>and</strong> Maintenance<br />
4.8.1 The water trap should be dismantled <strong>and</strong> the condition of the O-rings on the plunger<br />
checked <strong>and</strong> renewed if necessary. The interior of the water trap should be cleaned with fresh<br />
water <strong>and</strong> detergent.<br />
4.8.2 Similarly, any discolouration of the BPR flow meter may be removed by rinsing in fresh<br />
water.<br />
4.9 SAECO Valve Adjustment<br />
4.9.1 Check the setting of the SAECO valve. This may be done without removing the valve<br />
from the water trap assembly, by monitoring the diver supply gas pressure in the bell while<br />
carrying out the following checks.<br />
1. Increase the supply pressure to 50 psi. At this pressure, the valve should remain<br />
closed (that is, the indicating plunger should be down).<br />
2. Increase the supply pressure to 90 psi. The valve should now be fully open<br />
(indicator rod emerging from the top of the valve housing).<br />
3. Reduce supply pressure to 50 psi. Valve should again be closed.<br />
4.10 Relief valve Adjustment<br />
Bell Equipment Maintenance Schedule<br />
Every 500 Hours<br />
Next Due________Hrs.<br />
Dismantle, clean <strong>and</strong> inspect water trap (See Section 4.8).<br />
Every 3 Months<br />
Next Due________Hrs.<br />
Check operation of SAECO valve <strong>and</strong> bell equipment relief valves (see Sections 4.9 4.10).<br />
4.10.1 Remove each relief valve from the system <strong>and</strong> check their function by connecting<br />
directly to a suitable gas supply. Valves should be set as follows:<br />
Umbilical relief<br />
Water trap over Pressure relief valve<br />
Water trap negative Pressure relief valve<br />
Inward relieving valve at 3.5 bar (50 psi.)<br />
Outward relieving 2 bar (30 psi)<br />
Inward relieving 3.5 bar (50 psi)<br />
4.11 BPR Maintenance<br />
4.11.1 The BPR loader requires little or no maintenance. In the event of malfunction is should<br />
be returned to the factory for repair.<br />
Chap 4 Page 29 of 168 OM002 Rev 5