4.8 Water Trap Inspection <strong>and</strong> Maintenance<br />

4.8.1 The water trap should be dismantled <strong>and</strong> the condition of the O-rings on the plunger<br />

checked <strong>and</strong> renewed if necessary. The interior of the water trap should be cleaned with fresh<br />

water <strong>and</strong> detergent.<br />

4.8.2 Similarly, any discolouration of the BPR flow meter may be removed by rinsing in fresh<br />

water.<br />

4.9 SAECO Valve Adjustment<br />

4.9.1 Check the setting of the SAECO valve. This may be done without removing the valve<br />

from the water trap assembly, by monitoring the diver supply gas pressure in the bell while<br />

carrying out the following checks.<br />

1. Increase the supply pressure to 50 psi. At this pressure, the valve should remain<br />

closed (that is, the indicating plunger should be down).<br />

2. Increase the supply pressure to 90 psi. The valve should now be fully open<br />

(indicator rod emerging from the top of the valve housing).<br />

3. Reduce supply pressure to 50 psi. Valve should again be closed.<br />

4.10 Relief valve Adjustment<br />

Bell Equipment Maintenance Schedule<br />

Every 500 Hours<br />

Next Due________Hrs.<br />

Dismantle, clean <strong>and</strong> inspect water trap (See Section 4.8).<br />

Every 3 Months<br />

Next Due________Hrs.<br />

Check operation of SAECO valve <strong>and</strong> bell equipment relief valves (see Sections 4.9 4.10).<br />

4.10.1 Remove each relief valve from the system <strong>and</strong> check their function by connecting<br />

directly to a suitable gas supply. Valves should be set as follows:<br />

Umbilical relief<br />

Water trap over Pressure relief valve<br />

Water trap negative Pressure relief valve<br />

Inward relieving valve at 3.5 bar (50 psi.)<br />

Outward relieving 2 bar (30 psi)<br />

Inward relieving 3.5 bar (50 psi)<br />

4.11 BPR Maintenance<br />

4.11.1 The BPR loader requires little or no maintenance. In the event of malfunction is should<br />

be returned to the factory for repair.<br />

Chap 4 Page 29 of 168 OM002 Rev 5