March 2009<br />
4.2.3 If the diver gas supply pressure falls below a predetermined value, the springs will<br />
force the piston closed. An indicator is provided to show the status of the valve.<br />
Fig 3<br />
SAECO Valve Closed<br />
4.2.4 The SAECO valve should be adjusted so that it is fully closed when the gas supply<br />
pressure falls to 3.4 bar (50 psi) when bench tested on the surface. In practice the SAECO<br />
valve will close fully at higher supply pressures as a result of the negative pressure in the<br />
exhaust line. The adjustment procedure is described in Section 4.3.<br />
4.3 Water Trap<br />
4.3.1 The function of the water trap is to collect any free water, which may have entered the<br />
exhaust circuit. The water trap assembly is described in the diagrams overleaf.<br />
4.3.2 The water trap consists of an acrylic housing, a negative pressure gauge, overpressure<br />
relief valve, negative pressure relief valve, drain valve <strong>and</strong> isolating valve. The acrylic body<br />
should be mounted in a prominent position in the bell, giving the bellman an unobstructed view.<br />
The isolation valve enables the lower part of the water trap to be isolated from the upper section<br />
<strong>and</strong> vented by one simple operation, allowing the water trap to be drained without interrupting<br />
gas recovery.<br />
Chap 4 Page 23 of 168 OM002 Rev 5