March 09<br />
9.5 Electric Motor<br />
Low Oil Pressure: 1. Blocked Oil Suction filter 1. Remove filter, clean <strong>and</strong> degrease.<br />
2.Air leakage on suction side of oil 2.Check for tightness<br />
pump i.e. suction filter cover, plug<br />
in base of housing or face gasket<br />
of main bearing housing<br />
No oil pressure on<br />
initial start up<br />
(commissioning <strong>and</strong><br />
after overhaul):<br />
Low First Stage:<br />
3. Faulty oil pressure relief valve 3. Dismantle <strong>and</strong> examine spring ball<br />
<strong>and</strong> seat, renew components as<br />
necessary<br />
4. Incorrect oil pressure relief 4. Reset relief valve<br />
setting<br />
5. Worn or damaged compressor 5. Fit new bearings<br />
bearing<br />
6. Faulty or worn oil pump 6. Fit new pump<br />
7. Sump needs refilling 7. Replenish as necessary<br />
8. Faulty pressure gauge 8. Replace pressure gauge<br />
1. Wrong rotation 1. Check rotation<br />
2. Oil pump not primed 2. Concentric pump, remove pump.<br />
Fill with oil <strong>and</strong> replace.<br />
3. Faulty pressure gauge 3. Replace pressure gauge<br />
1. Valve not seating correctly in 1. Reseat or replace valve.<br />
first stage cylinder<br />
2. Air leak in piping between first 2. Locate leak <strong>and</strong> repair.<br />
stage delivery <strong>and</strong> second stage<br />
suction<br />
3. Air leak through pressure<br />
packing<br />
9.5.1 Type: Leroy Somer 37kw (50Hp) 400 V 3ph 50/60Hz<br />
3. Renew pressure packing<br />
High Interstage 1. Incorrect BPR setting. 1. Reset BPR loader<br />
Pressure:<br />
2. Change over valve in wrong 2. Change valve position.<br />
position for dive depth<br />
3. Volume tank over pressurised 3.Vent gas from volume tank<br />
4. Valves not seating correctly in 4. Reseat or replace valves<br />
second stage cylinder head<br />
5. Faulty pressure gauge 5. Replace pressure gauge<br />
Booster Overheating: 1. Seawater cooler blocked 1. Dismantle <strong>and</strong> clean<br />
High gas<br />
temperature:<br />
High gas pressure:<br />
1. Intercooler or after cooler 1. Dismantle <strong>and</strong> clean<br />
blocked<br />
1. Change over valve not switched 1. Switch change over valve.<br />
at<br />
OM002 Rev 5 Page 106 of 168 Chap 9