March 09<br />

9.5 Electric Motor<br />

Low Oil Pressure: 1. Blocked Oil Suction filter 1. Remove filter, clean <strong>and</strong> degrease.<br />

2.Air leakage on suction side of oil 2.Check for tightness<br />

pump i.e. suction filter cover, plug<br />

in base of housing or face gasket<br />

of main bearing housing<br />

No oil pressure on<br />

initial start up<br />

(commissioning <strong>and</strong><br />

after overhaul):<br />

Low First Stage:<br />

3. Faulty oil pressure relief valve 3. Dismantle <strong>and</strong> examine spring ball<br />

<strong>and</strong> seat, renew components as<br />

necessary<br />

4. Incorrect oil pressure relief 4. Reset relief valve<br />

setting<br />

5. Worn or damaged compressor 5. Fit new bearings<br />

bearing<br />

6. Faulty or worn oil pump 6. Fit new pump<br />

7. Sump needs refilling 7. Replenish as necessary<br />

8. Faulty pressure gauge 8. Replace pressure gauge<br />

1. Wrong rotation 1. Check rotation<br />

2. Oil pump not primed 2. Concentric pump, remove pump.<br />

Fill with oil <strong>and</strong> replace.<br />

3. Faulty pressure gauge 3. Replace pressure gauge<br />

1. Valve not seating correctly in 1. Reseat or replace valve.<br />

first stage cylinder<br />

2. Air leak in piping between first 2. Locate leak <strong>and</strong> repair.<br />

stage delivery <strong>and</strong> second stage<br />

suction<br />

3. Air leak through pressure<br />

packing<br />

9.5.1 Type: Leroy Somer 37kw (50Hp) 400 V 3ph 50/60Hz<br />

3. Renew pressure packing<br />

High Interstage 1. Incorrect BPR setting. 1. Reset BPR loader<br />

Pressure:<br />

2. Change over valve in wrong 2. Change valve position.<br />

position for dive depth<br />

3. Volume tank over pressurised 3.Vent gas from volume tank<br />

4. Valves not seating correctly in 4. Reseat or replace valves<br />

second stage cylinder head<br />

5. Faulty pressure gauge 5. Replace pressure gauge<br />

Booster Overheating: 1. Seawater cooler blocked 1. Dismantle <strong>and</strong> clean<br />

High gas<br />

temperature:<br />

High gas pressure:<br />

1. Intercooler or after cooler 1. Dismantle <strong>and</strong> clean<br />

blocked<br />

1. Change over valve not switched 1. Switch change over valve.<br />

at<br />

OM002 Rev 5 Page 106 of 168 Chap 9