Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Gasmizer Manual - Submarine Manufacturing and Products Ltd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
March 09<br />
12 SUCTION VALVE.................................................................................................................................... 135<br />
13 DELIVERY VALVE ASSEMBLY.............................................................................................................. 136<br />
14 COOLER WATER PUMP........................................................................................................................ 139<br />
15 STAGE 2 COOLER (AFTER COOLER).................................................................................................. 140<br />
16 COOLING WATER RELIEF VALVE........................................................................................................ 143<br />
17 BY-PASS VALVE .................................................................................................................................... 146<br />
18 IR 400/IR 500 SERIES............................................................................................................................ 147<br />
19 STAGE 1 - RELIEF VALVE ..................................................................................................................... 148<br />
20 STAGE 2 - RELIEF VALVE ..................................................................................................................... 149<br />
21 GAUGE PANEL ASSEMBLY.................................................................................................................. 150<br />
22 GAS BOOSTER STARTER PANEL........................................................................................................ 154<br />
23 BELT DRIVE TENSION ADJUSTMENT ................................................................................................. 155<br />
9.1 General Description<br />
The purpose of the Electric Gas Booster is to take the exhaust gas from the<br />
Reprocessing Unit at pressures, which vary according to dive depth <strong>and</strong> compress it to<br />
the appropriate supply pressure for that depth. Details of inlet <strong>and</strong> outlet pressure etc.<br />
can be found in the table below.<br />
Fig 1 Electric Gas Booster<br />
It can be seen from the table that the compression ratio of the plant falls as dive depth<br />
increases, therefore below a depth of 150 msw the first stage is no longer required <strong>and</strong><br />
must be manually bypassed. Pressure switches ensure that the booster shuts down if<br />
this is not done.<br />
OM002 Rev 5 Page 98 of 168 Chap 9