Airtight gas convectors<br />

2.6 Electronic series technical characteristics<br />

SYSTEMA S.p.A.<br />

.( .( .( .( .9( .9( .9( .)( .)( .)( .)(<br />

RATED HEAT FLOW<br />

WORKING HEAT OUTPUT<br />

kW 2 2,5 4 4,6 2,5 4 4,6 2,4 3 4,3 5,3<br />

kcal/h 1720 2150 3440 3960 2150 3440 3960 2070 2580 3700 4560<br />

kW 1,8 2,3 3,6 4,1 2,3 3,6 4,1 2,2 2,7 3,8 4,6<br />

kcal/h 1550 1980 3100 3530 1980 3100 3530 1900 2330 3270 3960<br />

COMBUSTION EFFICIENCY<br />

% 89,8 90,0 88,0 88,0 90,0 88,0 88,0 88,5 88,0 88,3 85,0<br />

CATEGORY EFFICIENCY<br />

1 1 1 1 1 1 1 1 1 1 1<br />

INJECTOR PRESSURE<br />

(power supply=20mbar)<br />

Methane G20 mbar 14,0 12,0 11,0 13,5 12,0 11,0 13,5 12,0 13,0 12,0 12,0<br />

INJECTOR PRESSURE<br />

(power supply=25mbar)<br />

INJECTOR PRESSURE<br />

(power supply=29mbar)<br />

INJECTOR PRESSURE<br />

(power supply=37mbar)<br />

BURNER INJECTOR<br />

DIAMETER<br />

MAX FUEL<br />

CONSUMPTION (0°C -<br />

1013 mbar)<br />

ELECTRICAL POWER SUPPLY<br />

ELECTRICAL POWER (absorbed)<br />

TREATED AMBIENT AIR FLOW<br />

HEATED AMBIENT VOLUME<br />

FAN SPEED NUMBER<br />

OVERALL<br />

DIMENSIONS<br />

Methane G20 mm 1,25 1,45 1,9 1,9 1,45 1,9 1,9 1,4 1,6 1,9 2,1<br />

Gas L - G25 mm 1,5 1,6 2,1 2,3 1,6 2,1 2,3 1,5 1,7 2,1 2,4<br />

GPL Butane - G30 mm 0,75 0,85 1 1,1 0,85 1 1,1 0,82 0,9 1,05 1,15<br />

GPL Propane - G31 mm 1,25 1,4 1,7 1,9 1,4 1,7 1,9 1,4 1,6 1,9 2<br />

Methane G20 m 3 0,21 0,26 0,42 0,49 0,26 0,42 0,49 0,25 0,32 0,46 0,56<br />

Gas L - G25 m 3 0,25 0,31 0,49 0,57 0,31 0,49 0,57 0,30 0,37 0,53 0,65<br />

GPL Butane - G30 kg/h 0,158 0,197 0,315 0,363 0,197 0,315 0,363 0,189 0,237 0,339 0,418<br />

GPL Propane - G31 kg/h 0,155 0,194 0,311 0,357 0,194 0,311 0,357 0,186 0,233 0,334 0,412<br />

V 230 230 230 230 230 230 230 230 230 230 230<br />

Hz 50 50 50 50 50 50 50 50 50 50 50<br />

W 20 20 20 20 45 65 65 65 65 85 85<br />

2 2 2 2 2 2 2<br />

Width mm 330 420 560 560 420 560 560 560 560 730 730<br />

Height mm 540 615 615 615 615 615 615 615 615 615 615<br />

Depth mm 250 250 250 250 250 250 250 250 250 250 250<br />

kg 26 32 46 46 32 46 46 32 33 52 52<br />

inches (”) 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F 3/8"- F<br />

Air mm 100 120 160 160 120 160 160 60 60 60 60<br />

Fumes mm 70 90 90 90 90 90 90 38 38 38 38<br />

WEIGHT<br />

GAS FITTING DIAMETER<br />

AIR-FUME COAXIAL<br />

PIPE DIAMETERS<br />

AIR-FUME MAX<br />

coaxial pipes mm<br />

LENGHT (*)<br />

TYPE OF EQUIPMENT<br />

CATEGORY OF EQUIPMENT<br />

7(&+1,&$/63(&,),&$7,2162)$,57,*+7*$6&219(&7256<br />

$7<br />

(/(&752121,&6(5,(602'(/6<br />

1219(17,/$7(' 9(17,/$7('<br />

Gas L - G25 mbar<br />

GPL Butane - G30 mbar<br />

13,5<br />

28,5<br />

12,5 11,0 10,0<br />

28,5 28,0 29,0<br />

GPL Propane - G31 mbar 36,5 37,0 35,5 37,0<br />

-<br />

12,5 11,0 10,0<br />

28,5 28,0<br />

37,0 35,5 37,0<br />

500 500 500<br />

II 2H3+<br />

29,0 28,5<br />

$7<br />

28,5 28,4<br />

28,6<br />

36,5 36,5 36,4 36,4<br />

m 3 /h -<br />

150 240 270 150 180 260 310<br />

m 3 36 46 72 82 50 78 88 48 58 84 102<br />

500 500 500 500<br />

C11<br />

1219(17,/$7('<br />

12,0 13,0 12,0 12,0<br />

5000 5000 5000 3000<br />

C13<br />

(*) N.B. One meter of length must be removed for every elbow used in forced ventilation<br />

electronic models (FE).<br />

9<br />

Rev. 05IT0112-1