SYSTEMA S.p.A.<br />

Airtight gas convectors<br />

e) Adjustment thermostat: this is a sensor-type thermostat that permits the temperature to<br />

be adjusted as required by the user for a comfortable room temperature, and also permits<br />

the control of the starting and switching off of the device from the control unit.<br />

THERMOSTAT CHARACTERISTICS<br />

Electrical power supply ................................................................240 V 20 A<br />

Work range ..................................................................................6° ÷ 30°C<br />

Max. bulb temperature .................................................................42°C<br />

Sensor .........................................................................................copper<br />

Bulb .............................................................................................copper<br />

f) Daily or weekly programmer (only on request): this serves to program the device’s<br />

daily and weekly operation cycles and is positioned on the control panel for access by the<br />

user for adjustment purposes.<br />

2.5 Pilot flame series technical characteristics<br />

7(&+1,&$/63(&,),&$7,2162)$,57,*+7*$6&219(&7256<br />

6(5,(6&(SU(1<br />

3,/27)/$0(7+(502&283/(6(5,(602'(/6<br />

1219(17,/$7('<br />

9(17,/$7('<br />

. . . . .9 .9 .9<br />

RATED HEAT FLOW<br />

WORKING HEAT OUTPUT<br />

kW<br />

kW<br />

2<br />

1,8<br />

2,5<br />

2,2<br />

4<br />

3,5<br />

4,6<br />

4,1<br />

2,5<br />

2,2<br />

4<br />

3,6<br />

4,6<br />

4,1<br />

kcal/h<br />

kcal/h<br />

1720<br />

1550<br />

2150<br />

1900<br />

3440<br />

3010<br />

3960<br />

3530<br />

2150<br />

1900<br />

3440<br />

3100<br />

3960<br />

3530<br />

COMBUSTION EFFICIENCY<br />

% 90,0 87,0 87,3 87,5 87,5 88,0 88,0<br />

CATEGORY EFFICIENCY 1<br />

INJECTOR PRESSURE<br />

Methane G20<br />

(power supply=20mbar)<br />

mbar 13.2 12.0 12.5 14.0 12.0 12.5 14.0<br />

INJECTOR PRESSURE<br />

Gas L - G25<br />

(power supply=25mbar)<br />

mbar<br />

-<br />

INJECTOR PRESSURE<br />

GPL Butane - G30<br />

(power supply=29mbar)<br />

mbar 28.9 28.8 28.9 29.0 28.8 28.9 29.0<br />

INJECTOR PRESSURE<br />

GPL Propane - G31<br />

(power supply=37mbar)<br />

mbar 36.6 36.8 36.7 36.5 36.6 36.7 36.5<br />

BURNER INJECTOR<br />

DIAMETER<br />

MAX FUEL<br />

CONSUMPTION (0°C -<br />

1013 mbar)<br />

ELECTRICAL POWER SUPPLY<br />

Methane G20 mm 1.25 1.45 1.90 1.90 1.45 1.90 1.90<br />

Gas L - G25 mm 1.25 1.45 1.90 1.90 1.45 1.90 1.90<br />

GPL Butane - G30 mm 0.75 0.85 1.05 1.10 0.85 1.05 1.10<br />

GPL Propane - G31 mm 0.75 0.85 1.05 1.10 0.85 1.05 1.10<br />

Methane G20 m 3 0.21 0.26 0.42 0.49 0.26 0.42 0.49<br />

Gas L - G25 m 3 0.25 0.31 0.49 0.57 0.31 0.49 0.57<br />

GPL Butane - G30 kg/h 0.158 0.197 0.315 0.363 0.197 0.315 0.363<br />

GPL Propane - G31 kg/h 0.155 0.194 0.311 0.357 0.194 0.311 0.357<br />

V -<br />

230 230 230<br />

Hz -<br />

50 50 50<br />

ELECTRICAL POWER (absorbed)<br />

W -<br />

25 30 30<br />

TREATED AMBIENT AIR FLOW<br />

m 3 /h -<br />

150 240 270<br />

HEATED AMBIENT VOLUME<br />

m 3 36 44 70 82 48 78 88<br />

FAN SPEED NUMBER -<br />

-<br />

2<br />

Width mm 330 420 560 560 420 560 560<br />

OVERALL<br />

Height<br />

mm<br />

615<br />

725<br />

DIMENSIONS<br />

Depth<br />

mm<br />

250<br />

WEIGHT<br />

kg 26 31 45 45 32 46 46<br />

GAS FITTING DIAMETER<br />

inches (”)<br />

3/8”M<br />

AIR-FUME COAXIAL Air mm 100 120 160 160 120 160 160<br />

PIPE DIAMETERS Fumes mm 70<br />

90<br />

AIR-FUME MAX<br />

LENGHT<br />

coaxial pipes mm<br />

500<br />

TYPE OF EQUIPMENT<br />

C11<br />

CATEGORY OF EQUIPMENT<br />

II 2H3+<br />

Rev. 05IT0112-1<br />

8