3.16 Malfunctions and solutions for electronic devices (Mod.<br />
K21E, K28E, K40E, K55E, K28VE, K40VE, K55VE, K21FE,<br />
K28FE, K40FE, K55FE)<br />
'()(&76 &$86(6 62/87,216<br />
1. The “red” lock-out light switches<br />
on.<br />
a) There is no gas or the pressure is a) Check the supply pressure on the<br />
too high.<br />
valve (5).<br />
b) Check the condition of the<br />
b) There is no electrical spark starting electrodes, the respective<br />
discharge on the burner.<br />
spark detection system, and the<br />
position of the starting electrodes.<br />
c) The electric polarity of the neutral c) Invert the polarity of the neutral<br />
phase has been inverted.<br />
phase.<br />
d) The device has not been correctly<br />
d) Ground the device correctly.<br />
grounded.<br />
e) There is a malfunction in the<br />
electronic unit (in most cases this is<br />
due to electrical discharges<br />
produced by lightning. We e) Replace using original spare<br />
recommend disconnecting the parts.<br />
electrical power supply during<br />
periods when the device will not be<br />
used.<br />
f) Air is present in the pipes and<br />
causes the device to lock-out after<br />
10 seconds of discharge on the<br />
burner.<br />
g) The centrifugal fan positioned in<br />
the combustion air suction circuit is<br />
malfunctioning (no starting occurs).<br />
f) Switch the bipolar switch<br />
equipped with the “orange l.e.d.” off<br />
and on to reset.<br />
g) Replace using original spare<br />
parts.<br />
2. The tangential fan for the supply<br />
of surrounding air fails to start<br />
working.<br />
a) The fan is jammed.<br />
a) Check and remove all foreign<br />
objects.<br />
b) The fan motor is malfunctioning. b) Replace the entire fan-motor unit.<br />
c) The fan triggering thermostat is<br />
malfunctioning (this can be checked<br />
by making an electric bridge on the<br />
thermostat itself).<br />
c) Replace the fan triggering<br />
thermostat (38 - 40 °C) using<br />
original spare parts.<br />