Download manual - Systema Polska Sp. z o.o.
Download manual - Systema Polska Sp. z o.o.
Download manual - Systema Polska Sp. z o.o.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Airtight gas convectors<br />
SYSTEMA S.p.A.<br />
Draw 28<br />
3.10 Electrical connections from the control panels to the devices<br />
Check to make sure that a good ground connection has been made and respect the correct<br />
connections of the phase and neutral wires. otherwise the flame detection and control systems<br />
will not work.<br />
3.11 Starting and operation of pilot flame devices (Mod. K21, K28,<br />
K40, K55, K28V, K40V, K55V)<br />
1) Set the dial (1) in the (î) position (¬) on the index (See Draw ).<br />
2) Press the dial (1) and keep it pressed down for approx. 10 seconds.<br />
3) Press the piezoelectric button (12) to light the burner’s pilot flame.<br />
4) After lighting the burner’s pilot flame, keep the dial (1) pressed down for approx. 10 seconds,<br />
and then release.<br />
5) Turn the dial (1) counter-clockwise to fire the main burner and set it on the index at values<br />
from 1 to 7 which correspond to 13 ° - 38 °C respectively.<br />
6) In order to switch the main burner off, rotate the dial (1) to the (î) position (¬) on the index.<br />
In order to switch the burner’s pilot flame off (and consequently the unit itself), turn the dial<br />
(1) to the (l) position (l) on the index.<br />
Wait 60 seconds before trying to start the device again.<br />
33<br />
Rev. 05IT0112-1