Airtight gas convectors<br />

SYSTEMA S.p.A.<br />

Draw 28<br />

3.10 Electrical connections from the control panels to the devices<br />

Check to make sure that a good ground connection has been made and respect the correct<br />

connections of the phase and neutral wires. otherwise the flame detection and control systems<br />

will not work.<br />

3.11 Starting and operation of pilot flame devices (Mod. K21, K28,<br />

K40, K55, K28V, K40V, K55V)<br />

1) Set the dial (1) in the (î) position (¬) on the index (See Draw ).<br />

2) Press the dial (1) and keep it pressed down for approx. 10 seconds.<br />

3) Press the piezoelectric button (12) to light the burner’s pilot flame.<br />

4) After lighting the burner’s pilot flame, keep the dial (1) pressed down for approx. 10 seconds,<br />

and then release.<br />

5) Turn the dial (1) counter-clockwise to fire the main burner and set it on the index at values<br />

from 1 to 7 which correspond to 13 ° - 38 °C respectively.<br />

6) In order to switch the main burner off, rotate the dial (1) to the (î) position (¬) on the index.<br />

In order to switch the burner’s pilot flame off (and consequently the unit itself), turn the dial<br />

(1) to the (l) position (l) on the index.<br />

Wait 60 seconds before trying to start the device again.<br />