Airtight gas convectors<br />

SYSTEMA S.p.A.<br />

7) Check for leakage of gas along the threaded joints.<br />

8) Fire the device, and make sure that the supply pressure to the burner is 29 mbar (*) using<br />

the pressure tap (5).<br />

9) Indicate on the rating plate the type of gas transformation performed on the device.<br />

(*) For LPG gas (Butane-Propane), a “I” stage pressure reducer must be installed near the<br />

tank in order to reduce the pressure to 1.5 bar; a “II” stage pressure reducer must be installed<br />

on the main external supply line in order to reduce the pressure to 29mbar (0.029 bar).<br />

Transformation from LPG gas to Methane gas<br />

1) Close the gas supply line and disconnect the electrical power supply.<br />

2) Remove the cast-iron front panel by unscrewing the four M8 screws at the corners.<br />

3) Remove the gas supply line pipe from the main burner (4) using the sealing connector (5)<br />

(See Draw ).<br />

4) Remove the nozzle-holder (6) and the nozzle (7), and replace the nozzle with the one<br />

contained in the transformation kit after first checking to make sure that the diameter<br />

corresponds to the diameter listed on the rating plate.<br />

5) Re-close the cast-iron front panel, making sure that the fiberglass sealing liner remains in<br />

place.<br />

6) Check for leakage of gas along the threaded joints.<br />

7) With a 20 mbar supply pressure read on the pressure tap (2), use the adjustment screw<br />

(3) to bring the pressure of the burner (1) to its nominal rating plate value. Screwing in the<br />

clockwise direction increases the pressure, while unscrewing counter-clockwise decreases<br />

the pressure.<br />

8) Indicate on the rating plate the type of gas transformation performed on the device.<br />