Download manual - Systema Polska Sp. z o.o.
Download manual - Systema Polska Sp. z o.o.
Download manual - Systema Polska Sp. z o.o.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Airtight gas convectors<br />
SYSTEMA S.p.A.<br />
3.6 Transformations for various types of gas supplies for pilot<br />
flame-type devices (Mod. K21, K28, K40, K55, K28V, K40V, K55V)<br />
Transformation must be performed only by qualified professionals in complete respect of the<br />
safety regulations in force. The Manufacturer declines all liability for erroneous installation or<br />
the inappropriate or incorrect transformation or use of the device.<br />
Transformation from Methane gas to LPG. gas<br />
1) Close the gas supply line and disconnect the electrical power supply.<br />
2) Remove the cast-iron front panel by unscrewing the four M8 screws at the corners.<br />
3) Remove the gas supply line pipe from the main burner (11) using the sealing connector<br />
(13) (See Draw ).<br />
4) Remove the nozzle-holder (14) and the nozzle (15), and replace the nozzle with the one<br />
contained in the transformation kit after first checking to make sure that the diameter<br />
corresponds to the diameter listed on the rating plate.<br />
5) Disable the valve's pressure regulator by screwing the screw (9) clockwise (+) all the way<br />
down.<br />
6) Remove the gas pipe (6) from the pilot, remove the pilot nozzle and replace it with the one<br />
contained in the transformation kit.<br />
7) Re-close the cast-iron front panel, making sure that the fiberglass sealing liner remains in<br />
place.<br />
8) Check for leakage of gas along the threaded joints.<br />
9) Start the device, and make sure that the supply pressure to the burner is 29 mbar (*) using<br />
the pressure tap (5).<br />
10) Indicate on the rating plate the type of gas transformation performed on the device.<br />
(*) For LPG gas (Butane-Propane), a “I” stage pressure reducer must be installed near the<br />
tank in order to reduce the pressure to 1.5 bar; a “II” stage pressure reducer must be<br />
installed on the main external supply line in order to reduce the pressure to 29mbar (0.029<br />
bar).<br />
Transformation from LPG gas to Methane gas<br />
1) Close the gas supply line and disconnect the electrical power supply.<br />
2) Remove the cast-iron front panel by unscrewing the four M8 screws at the corners.<br />
3) Remove the gas supply line pipe from the main burner (11) using the sealing connector<br />
(13) (See Draw ).<br />
4) Remove the nozzle-holder (14) and the nozzle (15), and replace the nozzle with the one<br />
contained in the transformation kit after first checking to make sure that the diameter<br />
corresponds to the diameter listed on the rating plate.<br />
5) Remove the gas pipe (6) from the pilot, remove the pilot nozzle and replace it with the one<br />
contained in the transformation kit.<br />
6) Re-close the cast-iron front panel, making sure that the fiberglass sealing liner remains in<br />
place.<br />
7) Check for leakage of gas along the threaded joints.<br />
8) With a 20 mbar supply pressure, use the adjustment screw (9) to bring burner pressure<br />
(4) to its nominal rating plate value. Screwing in the clockwise direction increases the<br />
pressure, while unscrewing counter-clockwise decreases the pressure.<br />
9) Indicate on the rating plate the type of gas transformation performed on the device.<br />
29<br />
Rev. 05IT0112-1