Airtight gas convectors<br />

SYSTEMA S.p.A.<br />

3.6 Transformations for various types of gas supplies for pilot<br />

flame-type devices (Mod. K21, K28, K40, K55, K28V, K40V, K55V)<br />

Transformation must be performed only by qualified professionals in complete respect of the<br />

safety regulations in force. The Manufacturer declines all liability for erroneous installation or<br />

the inappropriate or incorrect transformation or use of the device.<br />

Transformation from Methane gas to LPG. gas<br />

1) Close the gas supply line and disconnect the electrical power supply.<br />

2) Remove the cast-iron front panel by unscrewing the four M8 screws at the corners.<br />

3) Remove the gas supply line pipe from the main burner (11) using the sealing connector<br />

(13) (See Draw ).<br />

4) Remove the nozzle-holder (14) and the nozzle (15), and replace the nozzle with the one<br />

contained in the transformation kit after first checking to make sure that the diameter<br />

corresponds to the diameter listed on the rating plate.<br />

5) Disable the valve's pressure regulator by screwing the screw (9) clockwise (+) all the way<br />

down.<br />

6) Remove the gas pipe (6) from the pilot, remove the pilot nozzle and replace it with the one<br />

contained in the transformation kit.<br />

7) Re-close the cast-iron front panel, making sure that the fiberglass sealing liner remains in<br />

place.<br />

8) Check for leakage of gas along the threaded joints.<br />

9) Start the device, and make sure that the supply pressure to the burner is 29 mbar (*) using<br />

the pressure tap (5).<br />

10) Indicate on the rating plate the type of gas transformation performed on the device.<br />

(*) For LPG gas (Butane-Propane), a “I” stage pressure reducer must be installed near the<br />

tank in order to reduce the pressure to 1.5 bar; a “II” stage pressure reducer must be<br />

installed on the main external supply line in order to reduce the pressure to 29mbar (0.029<br />

bar).<br />

Transformation from LPG gas to Methane gas<br />

1) Close the gas supply line and disconnect the electrical power supply.<br />

2) Remove the cast-iron front panel by unscrewing the four M8 screws at the corners.<br />

3) Remove the gas supply line pipe from the main burner (11) using the sealing connector<br />

(13) (See Draw ).<br />

4) Remove the nozzle-holder (14) and the nozzle (15), and replace the nozzle with the one<br />

contained in the transformation kit after first checking to make sure that the diameter<br />

corresponds to the diameter listed on the rating plate.<br />

5) Remove the gas pipe (6) from the pilot, remove the pilot nozzle and replace it with the one<br />

contained in the transformation kit.<br />

6) Re-close the cast-iron front panel, making sure that the fiberglass sealing liner remains in<br />

place.<br />

7) Check for leakage of gas along the threaded joints.<br />

8) With a 20 mbar supply pressure, use the adjustment screw (9) to bring burner pressure<br />

(4) to its nominal rating plate value. Screwing in the clockwise direction increases the<br />

pressure, while unscrewing counter-clockwise decreases the pressure.<br />

9) Indicate on the rating plate the type of gas transformation performed on the device.<br />

29<br />

Rev. 05IT0112-1