PCI slot 1<br />

PCI slot 2<br />

ServeRAID-MR10is<br />

controller<br />

Note: The drive cage should be in the open position. This illustration shows it<br />

in the closed position.<br />

8. Press the ServeRAID-MR10is SAS/SATA controller firmly into the connector on<br />

the system board.<br />

9. Take the other end of the signal cable that is attached to the drive backplane<br />

section for drive bays 0 through 3 (as labeled on the front of the drive cage)<br />

and connect it to the connector that is closest to the battery on the<br />

ServeRAID-MR10is SAS/SATA controller.<br />

10. Replace the hard disk drive fan assembly:<br />

a. Insert the hard disk drive fan assembly retaining tab over the right edge of<br />

the hard disk drive backplane; then, rotate the hard disk drive fan assembly<br />

toward the backplane. Do not fully close the hard disk drive fan assembly.<br />

b. Route the signal cables and power cable through the slot on the edge of<br />

the hard disk drive fan assembly. Make sure that the cables will not be<br />

pinched between the hard disk drive fan assembly and the hard disk drive<br />

backplane when the assembly is installed.<br />

c. Rotate the hard disk drive fan assembly toward the backplane until the<br />

release tabs are fully engaged and snap into place.<br />

11. Reconnect the hard disk drive fan assembly cable to the system board.<br />

12. Rotate the drive cage back into the server until it stops; then, press and hold<br />

the retaining tab on top of the drive cage while you rotate the drive cage into<br />

the chassis until it is in the closed position.<br />

13. Reinstall the hard disk drives.<br />

Note: Before you continue, check all internal power cables to make sure that<br />

they are connected to the system board and other optional devices.<br />

14. Replace the side cover (see “Reinstalling the side cover” on page 64). Go to<br />

“Completing the installation” on page 62.<br />

15. Lock the side cover.<br />

16. Reconnect the external cables and power cords; then, turn on the attached<br />

devices and turn on the server.<br />

Chapter 2. Installing optional devices 57