Note: Before you continue, check all internal power cables to make sure that<br />

they are connected to the system board and other optional devices.<br />

14. Replace the side cover (see “Reinstalling the side cover” on page 64). Go to<br />

“Completing the installation” on page 62.<br />

15. Lock the side cover.<br />

16. Reconnect the external cables and power cords; then, turn on the attached<br />

devices and turn on the server.<br />

Installing the IBM ServeRaid-MR-10is VAULT SAS/SATA controller<br />

The optional IBM ServeRAID-MR10is VAULT SAS/SATA controller can be installed<br />

in either PCI slot 1 or 2 on the system board. The ServeRAID-MR10is adapter is<br />

supported on hot-swap server models only. The IBM ServeRAID-MR10is VAULT<br />

SAS/SATA adapter enables integrated RAID levels 0, 1, 5, 6, and 10 support<br />

capability on hot-swap hard disk drives. For configuration information, see the<br />

documentation on the ServeRAID CD that comes with the adapter.<br />

Important: To ensure that any of your ServeRAID-MR10i, ServeRAID-MR10is, or<br />

10M adapters function properly on UEFI-based servers, make sure that the adapter<br />

firmware level is updated to at least 11.xx-XXX, and the supporting drivers.<br />

Attention: Some cluster solutions require specific code levels or coordinated code<br />

updates. If the device is part of a cluster solution, verify that the latest level of code<br />

is supported for the cluster solution before you update the code.<br />

To install the ServeRAID-MR10is adapter, complete the following steps:<br />

1. Read the safety information that begins on page vii and “Installation guidelines”<br />

on page 29.<br />

2. Turn off the server and peripheral devices, and disconnect the power cords<br />

and all external cables.<br />

Attention: To avoid breaking the retaining clips or damaging the<br />

ServeRAID-MR10is adapter connector, open and close the clips gently.<br />

3. Unlock and remove the side cover (see “Removing the side cover” on page<br />

32).<br />

4. Remove the hard disk drive fan assembly:<br />

a. Rotate the hard disk drive fan assembly cable out of the system board.<br />

b. Remove all hard disk drives.<br />

c. Press and hold the drive cage release tab on the side of the drive cage;<br />

then, rotate the drive cage out of the chassis until the retaining tab on top<br />

of the cage locks into place.<br />

d. Pull out on the hard disk drive fan assembly release tabs (at the blue dots);<br />

then, rotate the hard disk drive fan assembly away from the drive cage<br />

slightly.<br />

5. Disconnect the signal and power cables and the existing SAS/SATA controller<br />

(if one is installed); then, remove the controller from the server.<br />

6. Touch the static-protective package that contains the ServeRAID-MR10is<br />

SAS/SATA controller to any unpainted metal surface on the server. Then,<br />

remove the ServeRAID-MR10is SAS/SATA controller from the package.<br />

7. Align the ServeRAID-MR10is SAS/SATA controller so that the keys align<br />

correctly with the connector on the system board.<br />

Attention: Incomplete insertion might cause damage to the system board or<br />

the ServeRAID-MR10is controller.<br />