Troubleshooting Tips<br />
ERROR/MESSAGE CODES<br />
ADD<br />
CAL<br />
CH-F<br />
CH-P<br />
CL-L<br />
CLR<br />
CON<br />
CPL<br />
FIL<br />
FULL<br />
HI-P<br />
OIL<br />
SCAL<br />
U-HI<br />
99LB<br />
There is less than six pounds (2.7 kilograms) of refrigerant in the<br />
tank. Add refrigerant to the tank.<br />
The scale is out of calibration. Calibrate the scale.<br />
The unit has recovered 300 pounds of refrigerant. Press SHIFT/<br />
RESET and FILTER at the same time, then replace the filterdrier.<br />
The vehicle’s A/C system has less than 25 psi. Do not attempt<br />
recovery if the A/C system has no refrigerant. Check for<br />
restrictions at access fittings. Check the manifold valve positions<br />
(they should be open). To continue, press HOLD/CONT.<br />
The low side clearing routine is in progress. This occurs when<br />
you press RECOVER and can last up to four minutes.<br />
The unit is in the self-clearing process.<br />
The vacuum pump will run continuously. Press SHIFT/RESET to<br />
stop.<br />
The specified cycle function (recovery, evacuation, charging or<br />
adding refrigerant) is complete.<br />
The filter-drier changeout is in progress.<br />
The refrigerant recovery tank is full. Replace the tank.<br />
The discharge pressure is above 435 psi. Check to be sure the<br />
unit tank’s red valve is open.<br />
The vacuum pump has run for 10 hours. While the “OIL”<br />
message is displayed, press SHIFT/RESET and ENTER at the<br />
same time to reset the timer. Then change the vacuum pump oil.<br />
The scale is damaged, disconnected, out of calibration or<br />
overloaded (it cannot exceed 80 pounds or 36.3 kilograms).<br />
Calibrate the scale.<br />
There is positive pressure on the vacuum pump. Press SHIFT/<br />
RESET and then RECOVER to remove the pressure, then<br />
continue the evacuation procedure.<br />
The maximum amount displayed during recovery is 99 pounds<br />
(or 99 kilograms). Press SHIFT/RESET to clear the display.<br />
38<br />
© 1998 Robinair, SPX Corporation