Troubleshooting Tips<br />

RECHARGING OPERATION<br />

No power when Main Power switch is on—no display showing<br />

Problem: Unit unplugged<br />

Solution:Plug the unit into a power source<br />

Problem: No power at wall outlet<br />

Solution:Locate the problem with the outlet or change outlets<br />

Audible tone sounds during refrigerant transfer<br />

Problem: Transfer stopped or too slow<br />

Solution:Start the A/C system and pull the remaining refrigerant into<br />

system. See RECHARGING THE A/C SYSTEM or<br />

Be sure the blue hose has access to the tank<br />

Problem: Refrigerant supply empty<br />

Solution:Add refrigerant to the tank<br />

Problem: Blue LIQUID tank valve closed<br />

Solution:Open the blue LIQUID tank valve<br />

Refrigerant does not flow<br />

Problem: Refrigerant supply empty<br />

Solution:Add refrigerant to the tank<br />

Problem: Flow restriction<br />

Solution:Check all connections on the A/C system (the 17700A/17701A<br />

should have adapters on both the low and high side fittings and<br />

the couplers on the 34700/34701 should be open), or<br />

Check the blue hose connection at the tank’s blue valve — be<br />

sure it is getting access, or<br />

Check the tank’s blue valve — it should be open, or<br />

Be sure the A/C system has had a minimum of 15 minutes of<br />

vacuum<br />

Vacuum pump runs, but low side gauge does not register an<br />

appropriate vacuum<br />

Problem: Pump oil contaminated<br />

Solution:Flush and change the vacuum pump oil<br />

Problem: Charging line loose<br />

Solution:Check connections<br />

Problem: Manifold leaking<br />

Solution:Check connections<br />

Problem: Low side valve closed<br />

Solution:Open low side valve<br />

Problem: 3 /8” hose improperly connected to pump<br />

Solution:Check connections<br />