Troubleshooting Tips<br />
RECHARGING OPERATION<br />
No power when Main Power switch is on—no display showing<br />
Problem: Unit unplugged<br />
Solution:Plug the unit into a power source<br />
Problem: No power at wall outlet<br />
Solution:Locate the problem with the outlet or change outlets<br />
Audible tone sounds during refrigerant transfer<br />
Problem: Transfer stopped or too slow<br />
Solution:Start the A/C system and pull the remaining refrigerant into<br />
system. See RECHARGING THE A/C SYSTEM or<br />
Be sure the blue hose has access to the tank<br />
Problem: Refrigerant supply empty<br />
Solution:Add refrigerant to the tank<br />
Problem: Blue LIQUID tank valve closed<br />
Solution:Open the blue LIQUID tank valve<br />
Refrigerant does not flow<br />
Problem: Refrigerant supply empty<br />
Solution:Add refrigerant to the tank<br />
Problem: Flow restriction<br />
Solution:Check all connections on the A/C system (the 17700A/17701A<br />
should have adapters on both the low and high side fittings and<br />
the couplers on the 34700/34701 should be open), or<br />
Check the blue hose connection at the tank’s blue valve — be<br />
sure it is getting access, or<br />
Check the tank’s blue valve — it should be open, or<br />
Be sure the A/C system has had a minimum of 15 minutes of<br />
vacuum<br />
Vacuum pump runs, but low side gauge does not register an<br />
appropriate vacuum<br />
Problem: Pump oil contaminated<br />
Solution:Flush and change the vacuum pump oil<br />
Problem: Charging line loose<br />
Solution:Check connections<br />
Problem: Manifold leaking<br />
Solution:Check connections<br />
Problem: Low side valve closed<br />
Solution:Open low side valve<br />
Problem: 3 /8” hose improperly connected to pump<br />
Solution:Check connections<br />
Series 17700A/17701A/34700/34701/34704 Enviro-Charge Units<br />
37