Maintenance Instructions<br />
CALIBRATING THE SCALE<br />
IMPORTANT!<br />
You must have a known exact weight of 40 lbs. ± .01 (18.14 kg ± .005)<br />
1. Remove all weight from the scale platform.<br />
2. Turn on the MAIN POWER switch.<br />
3. Press SHIFT/RESET and ENTER at the same time.<br />
4. Press 8-7-8-7. The display will show "A-1."<br />
NOTE: If you press any other key before the 8-7-8-7 sequence, you will not be<br />
able to enter the automatic calibration routine.<br />
5. Press 0 and then ENTER. The display will show "0.00" and then change to<br />
the A-2" message.<br />
6. Place a known exact weight of 10-60 lbs. on the center of the platform. Enter<br />
that weight on the display using the keypad, then press ENTER. The display<br />
will return to the vacuum mode.<br />
7. Check the scale accuracy by pressing SHIFT/RESET and ENTER and the<br />
same time. When the diagnostics mode is entered (the display is blank) press<br />
6. The display shows the amount of weight on the scale platform, and 0.00<br />
when it is removed.<br />