<strong>Operating</strong> Instructions<br />
IMPORTANT!<br />
Run the A/C<br />
system for a few<br />
minutes before<br />
starting the<br />
recovery process.<br />
Tests show more<br />
refrigerant is<br />
recovered if this<br />
action is taken.<br />
Turn the system<br />
off before<br />
proceeding.<br />
1. Connect the hoses to the vehicle as follows:<br />
17700A/17701A Series —<br />
• Attach the proper adapters to the low side and high side fittings on the vehicle.<br />
(An adapter package comes with each unit.)<br />
• Connect the unit’s 96” (244 cm) red high side hose to the adapter attached to<br />
the vehicle’s high side fitting.<br />
• Connect the unit’s 96” (244 cm) blue low side hose to the adapter attached to<br />
the vehicle’s low side fitting.<br />
34700/34701/34704 Series —<br />
• Connect the unit’s 96” (244 cm) red high side hose with the Quick-Coupler to<br />
the high side fitting of the A/C system, then open the<br />
coupler valve.<br />
• Connect the unit’s 96” (244 cm) blue low side hose with the Quick-Coupler to<br />
the low side fitting of the A/C system, then open the coupler valve.<br />
2. Check the manifold gauges on the unit’s control panel — they should both<br />
register above zero. If there is no system pressure, there is no refrigerant in the<br />
system to recover or the hoses are not connected properly.<br />
3. Be sure the oil drain valve is closed.<br />
4. Open both manifold valves on the control panel.<br />
Manifold Gauges<br />
INST0471<br />
Diagram of Control Panel<br />
Valves Open<br />
18<br />