INTRODUCTION<br />

The mini <strong>LAN</strong> cable tester complies with CE<br />

safety standard, compact size and lightweight<br />

design for easy detection of good connections,<br />

opens, crossed wires & split pairs by only one<br />

touch testing. Traces wires with tone. Remote<br />

lights allow one person operation. Additional<br />

non-contact voltage detection provides user<br />

safety. Ideal for testing installed cables or<br />

patch cords with RJ-45, RJ-11, RJ12 and<br />

BNC connectors.<br />

SAFETY RULES& WARNINGS<br />

1. Read all instruction in this manual before<br />

using this tester. Failure to do so may result<br />

in damage to the tester or injury to the user.<br />

2. Do not use this tester with its case open, or<br />

with parts removed. Doing so may damage<br />

the tester and/or injure the user.<br />

3. When using this tester in schools and<br />

workshops, responsible teachers or skilled<br />

personnel must control the usage of this<br />

tester. Failure to observe this precaution<br />

may result in damage to the tester or injury<br />

to the user.<br />

4. Follow the recommendations of any Trade<br />

Organizations or Regulatory Agencies<br />

whose scope encompasses the use of this<br />

tester failure to do so may result in damage<br />

to the tester or injury to the user.<br />

5. Repairs and maintenance must only be<br />

carried out by qualified service personnel or<br />

qualified electricians/technicians who know<br />

the dangers of.<br />

6. Do not apply voltage or current to any of the<br />

tester’s connectors. Doing so may damage<br />

the tester and /or injury the user.<br />

7. Remove the battery when the tester not in<br />

use for longer than a month. Chemical<br />

leakage from the battery could damage the<br />

tester.<br />

PRODUCT FEATURES<br />

1. Complies with CE safety standard<br />

2. Automatically detect good connections,<br />

opens, crossed wires & split pairs<br />

3. Simple one button test<br />

4. LEDs indicate connections and faults<br />

5. Tests shielded (STP)or unshielded(UTP)<br />

<strong>LAN</strong> cables<br />

6. BNC cable indicator<br />

7. Non-contact voltage detection for user<br />

safety.<br />

8. Long cable test more than 300 meters<br />

9. Low power consumption with auto power<br />

off function to preserve battery.<br />

SPECIFICATIONS<br />

1. Cables Tested: UTP and STP <strong>LAN</strong> cables<br />

Terminated in RJ-45 male connectors. (EIA/<br />

TIA 568)RJ-11, RJ-12 cables with male<br />

connectors, 2 to 6 connectors installed.<br />

BNC cables with male connectors.<br />

2. Faults Indicated: No Connection, Short,<br />

Straight, and Crossover.<br />

3. Low Battery Indicator: LED lights different<br />

colors to indicate low battery<br />

4. NCV detection for AC60V~240V 60Hz<br />

5. Case Dimensions:100*60*24.5mm(LxWxH)<br />

6. Weight:120g (without battery)<br />

7. Battery: 12V battery. AE23<br />

PRODUCT DESCRIPTION<br />

1. BNC connector<br />

2. Non-contact voltage<br />

indicator<br />

3. Power/sound on/off switch<br />

4. RJ-45/RJ-11/12 connector<br />

5. Auto / manual NCV switch<br />

6. One touch push button<br />

7. RJ-45/RJ-11/12 connector<br />

ACCESSORIES<br />

Female BNC Terminator<br />

Instruction Manual<br />

Pouch Bag<br />

OPERATION<br />

1. The MAIN and REMOTE unit:<br />

The Mini <strong>LAN</strong> Cable Tester consists of a<br />

main unit and a remote unit. The remote<br />

unit stores conveniently on the bottom of<br />

the main unit. It can be removed or<br />

replaced by sliding it from left to right or<br />

right to left respectively.<br />

2. Performing the test:<br />

Once the remote and main units are<br />

attached to the ends of the subject cable,<br />

as described in 3.2 and 3.3, testing may<br />

begin, simply press and release the test<br />

button on the main unit, observe the LED<br />

indicators, and note the beeping sound that<br />

comes from the main unit.<br />

3. Interpreting the results:<br />

3.1 Power LED:<br />

The power LED should lights up<br />

whenever the test button is pressed and<br />

released. If the power LED turns red,<br />

replace the battery.<br />

3.2 No connection LED<br />

If the remote is not connected to the<br />

main unit with a cable, or the cable has<br />

no intake conductors, the no connection<br />

LED will light up and the beeper will<br />

sound for 4 times.<br />

3.3 Straight/Crossover LED<br />

When all of the appropriate numbered<br />

LEDs light up, the straight or crossover<br />

LED also lights up, and the beeper<br />

sounds for 4 times with crossover.. the<br />

beeper sounds for 3 times with straight it<br />

means the cable is all correct<br />

connection. If some of the LEDs do not light<br />

up, but others light up, and the straight LED<br />

also lights up, it means the cable is open. If<br />

some of the LEDs light up inconsistently,<br />

and the straight LED also lights up, it<br />

means the cable may be misconnected.<br />

Please check in turn of lighted LED of<br />

remote unit to identify which wires are<br />

misconnected or change left side switch to<br />

“Step” become manual function to check<br />

the misconnection status step by step.<br />

If RJ45 or RJ11/12 all wires<br />

are wrong order that<br />

Straight LED will light<br />

1 to 8, 2 to 7 and so on.<br />

Note:<br />

RJ-11/12 cables may have 2 conductors, 4<br />

conductors, or 6 conductors. When testing 2<br />

conductor cables, LED 4 ~ 5 must light up, for<br />

4 conductor cables, LED 3~ 6 must light up<br />

and for 6 conductor cables, LED 2~7 must<br />

light up, and “STRAIGHT” LED also lights up.<br />

The numbered LEDs do not indicate a good<br />

connection exists; only shows connection<br />

exists. If “Short” LED lights up during test, it<br />

means the shorted was found in the cable.<br />

3.4 Short LED<br />

If 3 & 4 LEDs lights up, and all other<br />

LEDs do not light up, the cable is<br />

shorted; the “short” LED will light up.<br />

3.5 Crossover LED<br />

Numbered 1~8 LEDs will light up, and<br />

“Crossover” LED also lights up. Means<br />

wires are crossover or wire crossed.<br />

4. BNC testing:<br />

Numbered LEDs will light up during<br />

scanning, after scanning; both LEDs of<br />

BNC on the main unit and the BNC receiver<br />

will light up. If the BNC cable is short, only<br />

the LED of BNC on the main unit lights up;<br />

if the BNC cable is open, both LEDs of BNC<br />

on the main unit and the receiver won’t light<br />

and “no connection” LED will light up..<br />

5. Non-contact Voltage Detection:<br />

Set the left side switch to the NCV position<br />

and push the test button, As the detachable<br />

antenna is located at the right top of the<br />

tester, close to right top of the tester to the<br />

live wires, the LEDs of NCV will light with<br />

sound.<br />

Please put the tester as close as<br />

possible to surface of tested<br />

source for optima testing result.<br />

When the wire multiple faults, test results<br />

show is in accordance with the host panel<br />

"test results show" the lights from the top<br />

down order, namely: Shot → Straight →<br />

Crossover → No Connection!


迷 你 網 路 測 試 器<br />

<strong>MT</strong>-<strong>7058</strong><br />

一 、 產 品 介 紹 :<br />

<strong>MT</strong>-<strong>7058</strong> 是 一 款 集 多 種 線 路 測 試 功 能 及 非<br />

接 觸 電 壓 測 量 於 一 體 的 多 功 能 纜 線 測 試<br />

器 , 可 測 試 的 線 材 種 類 RJ-45、RJ-11、<br />

RJ-12、BNC。 只 需 一 按 開 關 , 所 測 試 線<br />

材 狀 況 一 目 了 然 。 線 材 的 斷 路 、 短 路 、 交<br />

錯 都 一 一 顯 示 在 主 機 面 板 上 。<br />

二 、 安 全 注 意 事 項 :<br />

注 意 : 此 測 試 器 不 能 用 於 測 試 帶 有 電 壓 之<br />

活 線 , 若 將 活 線 接 於 此 測 試 器 , 可<br />

能 會 造 成 測 試 器 損 壞 。<br />

** 使 用 前 請 細 詳 閱 讀 使 用 說 明 書 , 錯 誤 使<br />

用 可 能 造 成 測 試 器 損 壞 。<br />

** 使 用 時 請 勿 將 機 殼 打 開 使 用 或 自 行 更<br />

換 內 部 零 件 , 以 免 成 測 試 器 損 壞 。<br />

三 、 產 品 特 色 :<br />

雙 功 能 指 示 : 快 速 結 果 測 試 ( 斷 路 . 交<br />

叉 . 直 通 . 短 路 ) 與 Pin to Pin 掃 描 測 試<br />

(1-8 LEDs)<br />

網 路 . 電 話 .BNC 3 合 1: 可 測 試 RJ45<br />

(8P8C) 網 路 線 、RJ11/12 (4P/2C.<br />

6P/4C. 6P/6C) 電 話 線 、BNC 線 與 屏<br />

蔽 指 示<br />

聲 光 雙 顯 示 : 具 有 LED 燈 號 與 音 頻 嗶<br />

聲 的 聲 光 雙 指 示 功 能 、 電 池 低 電 壓 指<br />

示 、 防 誤 測 迴 路 保 護 電 路<br />

免 接 觸 驗 電 : 具 有 免 接 觸 驗 電 功 能 ,<br />

確 保 網 路 架 設 作 業 的 安 全 , 並 通 過 CE<br />

安 規 認 證<br />

測 試 距 離 更 遠 : 採 用 12V(AE23) 電<br />

池 , 測 試 距 離 超 過 300 米<br />

攜 帶 方 便 : 輕 巧 迷 你 的 近 遠 端 結 合 設<br />

計 , 附 BNC 終 端 電 阻 . 攜 存 袋 , 外 出<br />

作 業 更 方 便<br />

四 、 產 品 規 格 :<br />

1. 測 試 線 材 / 接 頭 :UTP / STP / RJ-11/<br />

RJ-12 / RJ45 / BNC<br />

2. 自 動 (AUTO) 及 手 動 (STEP) 切 換 掃<br />

描 檢 測 跳 接 正 確 性 、 短 路 、 斷 路 及 芯<br />

線 排 列 順 序 等 功 能<br />

3. 非 接 觸 電 壓 AC60V~240V 60Hz 感<br />

應 測 試 (NCV)<br />

4. BNC 接 頭 同 軸 電 纜 連 接 、 斷 路 、 短<br />

路 測 試<br />

5. 自 動 待 機 功 能<br />

6. 低 電 壓 LED 燈 色 指 示<br />

7. 尺 寸 :100*60*24.5mm (L x W x H)<br />

8. 重 量 :120 克 ( 不 含 電 池 )<br />

9. 適 用 電 源 :12V 電 池 AE23<br />

五 、 本 體 介 紹 ..<br />

1. BNC 接 頭<br />

2. 免 接 觸 驗 電 顯 示<br />

3. 電 源 / 聲 音 開 關<br />

4. RJ-45/11/12 接 頭<br />

5. 自 動 / 手 動 / 免 接 觸<br />

驗 電 開 關<br />

6. 測 試 按 鈕<br />

7. RJ-45/11/12 接<br />

頭<br />

六 、 配 件 :<br />

1. BNC 母 端 接 頭<br />

2. 使 用 說 明 書<br />

3. 收 納 袋<br />

4. 12V (AE23) 電 池<br />

七 、 顯 示 面 板 及 LED 燈 功 能 介 紹 :<br />

(1) “S" 燈 號 : 表 示 遮 罩 線<br />

(2) “1 -8" 燈 號 : 表 示 對 應 的 線 路 。<br />

(3) “SHORT” 燈 號 : 表 示 線 材 有 短 路 。<br />

(4) “STRAIGHT" 燈 號 : 表 示 受 測 試 的<br />

線 材 連 接 是 正 確 的 或 是 代 表 一 條 扁<br />

平 的 直 通 線 。<br />

RJ45 (8P8C) 網 路 線 和 RJ11/12<br />

(4P/2C. 6P/4C. 6P/6C) 電 話 線 兩 端<br />

的 順 序 全 反 向 時 ( 即 一 線 材 端 是 1~<br />

8, 另 一 端 是 8~1) 測 試 結 果 為<br />

“STRAIGHT" 燈 亮 起 , 蜂 鳴 器 響 3<br />

聲 。 此 類 , 請 結 合 主 測 試 器 和 遠 端 測<br />

試 器 判 斷 線 材 的 情 況 。<br />

(5) “CROSSOVER" 燈 號 : 表 示 受 測 試<br />

的 線 材 連 接 有 交 錯 的 問 題 或 是 代 表<br />

一 條 交 叉 的 對 絞 線 。<br />

(6) “NO CONNECTION" 燈 號 : 表 示 沒<br />

有 相 通 的 線 , 或 是 接 頭 沒 有 插 好 , 有<br />

可 能 是 接 觸 不 良 。<br />

(7) “POWER" 燈 號 : 按 下 測 試 鍵 後 亮 綠<br />

燈 : 表 示 本 測 試 器 的 電 源 正 常 可 正 常<br />

使 用 。 亮 紅 燈 : 表 示 本 測 試 器 的 電 源<br />

不 足 , 應 及 時 更 換 電 池 , 以 免 對 測 試<br />

結 果 產 生 影 響 。<br />

(8) “NCV" 燈 號 .. 表 示 接 觸 電 線 存 在<br />

電 壓<br />

(9) “BNC" 燈 號 .. 同 軸 電 纜 導 通 判 斷<br />

八 、3 種 線 材 及 NCV 的 測 試 方 法<br />

1. 測 試 RJ45:<br />

主 測 試 器 的 測 試 結 果 皆 需 搭<br />

配 遠 端 接 收 器 亮 燈 順 序 來 判<br />

斷 線 路 正 確 性<br />

把 所 需 測 試 線 插 入 主 測 試 器 和 遠 端 測<br />

試 器 , 按 一 下 開 關 主 機 "STRAIGHT<br />

" 燈 亮 , 而 上 方 對 應 的 8 顆 LED 燈 亮<br />

起 順 序 一 致 時 ( 如 果 是 STP 線 則 "S<br />

" 燈 也 會 同 時 亮 ), 表 示 這 條 線 是 連 接<br />

正 確 的 線 路 。<br />

如 果 "STRAIGHT" 或<br />

“CROSSOVER" 燈 亮 , 而 主 測 試 器 和<br />

遠 端 測 試 器 燈 號 亮 起 的 順 序 不 一 致 就<br />

表 示 有 交 錯 或 順 序 相 反 。 此 時 只 要 查<br />

看 遠 端 接 收 器 燈 號 亮 起 的 順 序 即 可 得<br />

知 是 哪 幾 條 線 錯 接 。<br />

將 側 面 的 滑 動 開 關 切 換 至 ”STEP” 手 動<br />

測 試 功 能 , 逐 一 查 看 主 測 試 器 及 接 收<br />

器 1-8 燈 號 顯 示 狀 態 。<br />

如 果 "SHORT" 燈 亮 , 表 示 有 短 路 ,<br />

同 時 短 路 的 路 線 與 所 對 應 的 LED 燈 也<br />

同 時 亮 。<br />

如 果 "STRAIGHT" 燈 亮 , 而 LED 燈<br />

有 幾 顆 不 亮 , 表 示 對 應 的 路 線 有 斷 路 。<br />

如 果 "CROSSOVER" 燈 亮 , 就 表 示<br />

這 條 線 是 交 叉 線 或 錯 接 。.<br />

2. 測 試 RJ-11/12:<br />

如 果 6 芯 電 話 線 則 LED 亮 “2-7",4<br />

芯 電 話 線 亮 “3-6",2 芯 電 話 線 “4-5”,<br />

同 時 “STRAIGHT" 燈 也 亮 。<br />

3. 測 試 BNC 同 軸 電 纜 :<br />

插 入 BNC 測 試 座 , 配 合 BNC 母 端 接 頭 ,<br />

按 下 測 試 鍵 , 掃 描 後 若 電 纜 線 導 通 狀<br />

態 , 則 “BNC" 指 示 及 母 端 接 頭 燈 亮 。<br />

若 電 纜 線 開 路 , 則 “NO<br />

CONNECTION" 指 示 燈 亮 . “BNC” 指<br />

示 燈 及 母 端 接 頭 燈 不 亮 , 若 電 纜 線 短<br />

路 , 則 “BNC” 指 示 燈 亮 , 母 端 接 頭 燈<br />

不 亮<br />

4. NCV 測 試 :<br />

將 左 側 撥 動 開 關 推 到 NCV 檔 位 , 按 下<br />

TEST 鍵 , 並 將 本 體 右 測 頂 端 靠 近 被 測<br />

體 , 當 交 流 電 壓 高 於 60V 低 於 240V<br />

時 ,“NCV" 指 示 LED 長 亮 並 有 響 聲 警<br />

示 。<br />

為 提 高 測 試 靈 敏 度 , 請 貼 近 待<br />

測 電 源 表 面 。<br />

當 線 材 多 重 故 障 時 ,「 測 試 結<br />

果 顯 示 」 的 優 先 排 序 , 是 依 照 主 機 面 板 上<br />

「 測 試 結 果 顯 示 」 的 燈 號 由 上 而 下 的 順<br />

序 , 即 :Shot→Straight→Crossover→No<br />

Connection!<br />

©2013 Prokit’s Industries Co., LTD. All rights reserved 2013002( T)