Troubleshooting Tips<br />
RECOVERY AND VACUUM OPERATION<br />
Compressor does not start or stop prematurely<br />
Problem:<br />
Solution:<br />
No power.<br />
Check for power at plug or outlet.<br />
Problem:<br />
Solution:<br />
**OVERLOAD** is displayed.<br />
Move refrigerant from unit tank to approved refrigerant storage<br />
tank. See RECHARGING A/C SYSTEM.<br />
Problem:<br />
Solution:<br />
HIGH PRESSURE is displayed.<br />
Be sure tank valves are open and hoses are correctly connected<br />
to the unit tank.<br />
Problem:<br />
Solution:<br />
**SCALE** is displayed.<br />
The scale is damaged, disconnected, out of calibration or overloaded.<br />
Runs but gauges won't indicate 13 in Hg (0.44 BAR)<br />
Problem:<br />
Solution:<br />
Oil drain valve open.<br />
Close the oil drain valve.<br />
Problem:<br />
Solution:<br />
Leak in vehicle system.<br />
Locate and repair all system leaks.<br />
Problem:<br />
Solution:<br />
Manifold valves not open.<br />
Open valves.<br />