3–<strong>Fabric</strong> <strong>Manager</strong> Configuration<br />

Configuring the <strong>QLogic</strong> <strong>Fabric</strong> <strong>Manager</strong><br />

Table 3-2. Shared Parameters (Continued)<br />

LogFile<br />

Parameter<br />

Default<br />

Value<br />

Description<br />

Sets log output location for SM, PM, BM and<br />

FE. By default (or if this parameter is empty)<br />

log output is accomplished using syslog.<br />

However, if a LogFile is specified, logging<br />

will be done to the given file. LogMode<br />

further controls logging.<br />

This parameter is ignored for the <strong>QLogic</strong><br />

Embedded <strong>Fabric</strong> <strong>Manager</strong>. Consult the<br />

<strong>QLogic</strong> 12000 Chassis User’s <strong>Guide</strong> for<br />

information on configuring chassis logging<br />

options.<br />

LogMode 0 Controls mode for logging by SM, PM, BM<br />

and FE.<br />

low two bits control logging as follows:<br />

Low Bit (0/1):<br />

0 - use normal logging levels<br />

1 - logging is quieted by downgrading the<br />

majority of fatal, error, warn and infiniinfo log<br />

messages to level 3 (INFO) and only outputting<br />

user actionable events when LogLevel<br />

is 1 or 2<br />

Next Bit (0/2) (only affects logging when<br />

LogFile specified):<br />

0 - user actionable events go to syslog and<br />

LogFile<br />

2 - when LogFile specified, nothing goes to<br />

syslog<br />

This parameter is ignored for the Embedded<br />

<strong>Fabric</strong> <strong>Manager</strong>. Consult the <strong>QLogic</strong> 12000<br />

Chassis User’s <strong>Guide</strong> for information on<br />

configuring chassis logging options.<br />

SyslogFacility local6 For the Host FM, controls what syslog facility<br />

code is used for log messages,<br />

Allowed values are: auth, authpriv, cron,<br />

daemon, ftp, kern, local0-local7, lpr, mail,<br />

news, syslog, user, or uucp.<br />

For the Embedded FM, this parameter is<br />

ignored<br />

3-8 IB0054608-01 B