B–<strong>QLogic</strong> <strong>Fabric</strong> <strong>Manager</strong> Log Messages<br />

Other Log Messages<br />

Get NodeInfo failed for node off Port x of Node 0x00066a00d9000143:Hca1, status=7<br />

SM Area: Discovery.<br />

Meaning: The node connected to port x of HCA1 is not responding.<br />

Action: Check the health of the node connected to the port.<br />

Get NodeDesc failed for node off Port X of Node 0x00066a00d9000143:Hca1, status = 7<br />

SM Area: Discovery.<br />

Meaning: The node connected to port x of HCA1 is not responding.<br />

Action: Check the health of the node connected to the port.<br />

Failed to get Switchinfo for node sw1 guid 0x00066a00d9000143: status = 7<br />

SM Area: Discovery.<br />

Meaning: Switch node 1 is not responding.<br />

Action: If the condition persist, check the health of the switch and capture<br />

health data if possible.<br />

Failed to set Switchinfo for node sw1 nodeGuid 0x00066a00d9000143: status = 7, port<br />

mkey=0x0, SM mkey=0x0<br />

SM Area: Discovery.<br />

Meaning: Switch node 1 not responding.<br />

Action: If the condition persist, check the health of the switch and capture<br />

health data if possible.<br />

Failed to get PORTINFO from port 1 of node [x] Hca1; Marking port Down!<br />

SM Area: Discovery.<br />

Meaning: Port x of HCA1 not responding.<br />

Action: Check the health of node HCA1.<br />

Failed to init switch-to-switch link from node [x] sw1 guid 0x00066a00d9000143 port index<br />

X to node [x] sw2 guid 0x00066a00d9000144 port index Y which was<br />

reported down<br />

SM Area: Discovery.<br />

Meaning: May be caused by simultaneous removal/insertion events in the<br />

fabric.Persistence indicates a possible bad inter-switch cable or<br />

malfunctioning leaf or spine switch component.<br />

Action: If the situation persist, perform a health check on the 2 switch<br />

ports. Replace the cable or switch component.<br />