5–Embedded <strong>Fabric</strong> <strong>Manager</strong> Commands and Configuration<br />

Subnet Management Group CLI Commands<br />

smConfig<br />

Authority<br />

Syntax<br />

Keywords<br />

Configure startup parameters of the embedded subnet manager.<br />

smConfig [query] [startAtBoot yes|no] [startOnSlaveCmu yes|no]<br />

query<br />

Display present settings, no change.<br />

startAtBoot yes | no<br />

yes – Start the subnet manager at chassis boot.<br />

no – Do not start the subnet manager at chassis boot.<br />

startOnSlaveCmu yes | no<br />

yes – Start the subnet manager on the slave CMU.<br />

no – Do not start the subnet manager on the slave CMU.<br />

Notes<br />

Examples<br />

Use this command to configure the subnet manager. Changes to these<br />

parameters will not take effect until the next reboot of the Chassis Management<br />

Card(s).<br />

This command can only be run on the master Chassis Management Card.<br />

-> smconfig query<br />

startAtBoot: no<br />

startOnSlaveCmu: no<br />

-><br />

-or-<br />

-> smConfig<br />

Start at boot [Y]<br />

Start on slave CMU [N]<br />

-><br />

-or-<br />

-> smconfig startAtBoot yes startOnSlaveCmu yes<br />

Saving....<br />

Saving complete...<br />

5-4 IB0054608-01 B