3–<strong>Fabric</strong> <strong>Manager</strong> Configuration<br />

Configuring the <strong>QLogic</strong> <strong>Fabric</strong> <strong>Manager</strong><br />

Table 3-10. Sm <strong>Fabric</strong> Configuration Parameters (Continued)<br />

Parameter<br />

Default<br />

Value<br />

Description<br />

QueryValidation 0 When 1, enables IBTA compliant SA query<br />

operation for GetTable (PathRecord). As<br />

such a SGID and NumbPath is required<br />

When 0, allows interop with some<br />

non-compliant OFED queries and permits<br />

GetTable (PathRecord) to specify either a<br />

SGID or SLID and defaults numbPath to<br />

127 if not specified.<br />

SmaBatchSize 2 This and the following two parameters control<br />

how many concurrent SMA requests the<br />

SM can have in flight while programming<br />

the SMAs in the fabric.<br />

EhcaSmaBatchSize 1 Max parallel reqs to ehca SMA<br />

MaxParallelReqs 4 Max devices to req in parallel<br />

SmaEnableLRDR 1 Controls use of mixed LID Routed (LR) and<br />

Directed Routed (DR) SMPs during programming<br />

of the fabric. The use of mixed<br />

LR-DR SMPs can improve SM sweep time<br />

and reduce the time for SM to respond to<br />

fabric changes. All <strong>QLogic</strong> Host Channel<br />

Adapters and Switches support LR-DR<br />

SMPs.<br />

It can have the following values<br />

0 – SM will not use any mixed LR-DR SMPs<br />

1 – SM will use mixed LR-DR SMPs.<br />

2 – SM will attempt using mixed LR-DR<br />

SMPs, but if a particular switch does not<br />

respond to these SMPs, it will fallback to<br />

using pure DR SMPs for initializing nodes<br />

connected to that switch.<br />

EhcaSmaEnableLRDR 0 Controls use of mixed LID Routed (LR) and<br />

Directed Route (DR) SMPs during programming<br />

of IBM eHCA Logical Switches<br />

0 – never send a LRDR SMP to an IBM<br />

eHCA Logical switch<br />

1 – enable use of LRDR SMPs for IBM<br />

eHCA Logical switches. This only has effect<br />

when SmaEnableLRDR is 1 or 2.<br />

IB0054608-01 B 3-33