PA-28R-201 SOP 53<br />
10. ELECTRIC FUEL PUMP OFF<br />
Depress the ELECTRIC FUEL PUMP switch to the OFF position and check<br />
that the fuel pressure decreases slightly.<br />
11. AMMETER/ANNUNCIATORS CHECK<br />
CHECK the AMMETER for indication of an appropriate load.<br />
CAUTION<br />
If the starter contactor remains closed after engine start<br />
(causing the starter to remain engaged), an excessively high<br />
load indication will be indicated. In this event, immediately shut<br />
down the engine and contact the Fleet Maintenance<br />
Department.<br />
Do not attempt flight if there is no indication of primary<br />
alternator output.<br />
After the engine has been started, CHECK to ensure that all<br />
ANNUNCIATOR lights are extinguished.<br />
12. ENGINE START CHECKLIST COMPLETE<br />
Upon completion of the ENGINE START CHECKLIST, verify that all items<br />
have been accomplished and that the <strong>checklist</strong> is COMPLETE.<br />
Rev 06 © <strong>Embry</strong>-<strong>Riddle</strong> <strong>Aeronautical</strong> <strong>University</strong> Revised 07-01-2012