148 PA-28R-201 SOP<br />
ELECTRICAL FAILURE CHECKLIST<br />
ALT annunciator light illuminates.<br />
1. AMMETER .................................................................. CHECK/VERIFY<br />
2. ELECTRICAL LOAD ............................................................... REDUCE<br />
3. ALTERNATOR SWITCH ................................................................ OFF<br />
4. ALTERNATOR CIRCUIT BREAKER .......................... CHECK (RESET)<br />
5. ALTERNATOR SWITCH (after 1 second) ......................................... ON<br />
If power is not restored:<br />
6. ALTERNATOR SWITCH ................................................................ OFF<br />
7. ELECTRICAL LOAD ............................................................... REDUCE<br />
8. AIRPORT ..................................................................................... LAND<br />
9. ELECTRICAL FAILURE CHECKLIST ................................. COMPLETE<br />
1. AMMETER CHECK/VERIFY<br />
CHECK the AMMETER to VERIFY that the alternator has failed (zero<br />
reading).<br />
NOTE<br />
Verify a failed alternator by turning on an electrically-powered<br />
device (such as a landing light). If no increase in ammeter<br />
reading is noted, assume the alternator has failed.<br />
2. ELECTRICAL LOAD REDUCE<br />
REDUCE the ELECTRICAL LOAD by turning off non-essential electricallypowered<br />
devices.<br />
3. ALTERNATOR SWITCH OFF<br />
Depress the ALTERNATOR SWITCH to the OFF position.<br />
4. ALTERNATOR CIRCUIT BREAKER CHECK (RESET)<br />
CHECK that the CIRCUIT BREAKER for the alternator is IN. If not, RESET<br />
the circuit breaker to the IN position.<br />
5. ALTERNATOR SWITCH (after 1 second) ON<br />
Depress the ALTERNATOR SWITCH to the OFF position.<br />
If power is not restored:<br />
6. ALTERNATOR SWITCH OFF<br />
Depress the ALTERNATOR SWITCH to the OFF position.<br />
Revised 07-01-2012 © <strong>Embry</strong>-<strong>Riddle</strong> <strong>Aeronautical</strong> <strong>University</strong> Rev 06