Rapid <strong>EIA</strong> <strong>Studies</strong> <strong>of</strong> 3 <strong>Pre</strong>-identified <strong>Hazardous</strong> <strong>Waste</strong> <strong>Disposal</strong> <strong>Sites</strong> <strong>in</strong> NCT - Delhi<br />

Page No.132<br />

The quality <strong>of</strong> the groundwater shows: (I) Lead concentration values exceed 0.05<br />

ppm <strong>in</strong> 1 U/s, 4 D/s locations, (ii) Hardness values exceed 600 ppm <strong>in</strong> 8<br />

locations (5 D/s, 3 U/s), (iii) Fluoride values exceed 1.5 ppm <strong>in</strong> 2 U/s, 2 D/s<br />

locations, (iv) TDS value exceeds 2000 ppm <strong>in</strong> 3 U/s, 5 D/s locations.<br />

Based on 50 years ra<strong>in</strong>fall data, average annual ra<strong>in</strong>fall is reported to be 905.32<br />

mm.<br />

Based on monitor<strong>in</strong>g <strong>of</strong> ambient air quality at the site for 3 days (24 hours<br />

cont<strong>in</strong>uously), concentration <strong>of</strong> SPM, SO x and NO x at the site were <strong>in</strong> the range<br />

<strong>of</strong> 145 - 160, 1.6 - 1.8 and 1.5 - 2.1 ug/nm 3 respectively. The presence <strong>of</strong> the<br />

SPM, SO x and NO x <strong>in</strong> ambient air quality is well below the prescribed national<br />

Ambient Air Quality standards for <strong>in</strong>dustrial areas/residential areas.<br />

While carry<strong>in</strong>g out excavation and construction <strong>of</strong> the landfill, periodic water spray<br />

has been recommended <strong>in</strong> order to suppress dust.<br />

Based on the f<strong>in</strong>d<strong>in</strong>gs <strong>of</strong> <strong>EIA</strong> studies, the above project can be considered as<br />

less pollut<strong>in</strong>g project<br />

The leachate generated secured landfill facility will be collected systematically <strong>in</strong><br />

the collection pit and will be pumped to the Treatment Plant for further treatment<br />

before disposal <strong>in</strong>to environment.<br />

To prevent soil erosion after closure <strong>of</strong> the facility, vegetative cover will be<br />

developed on top <strong>of</strong> the l<strong>in</strong>er system.<br />

Green belt will be developed surround<strong>in</strong>g the secured landfill facility <strong>in</strong> order to<br />

abate air & noise pollution and to reduce the storm water dra<strong>in</strong>age.<br />

The development <strong>of</strong> this facility will facilitate the systematic collection, storage,<br />

handl<strong>in</strong>g, transportation, process<strong>in</strong>g and disposal <strong>of</strong> the hazardous wastes<br />

generated from 28 approved <strong>in</strong>dustrial areas/estates <strong>in</strong> Delhi without effect<strong>in</strong>g<br />

the surround<strong>in</strong>g environment. This would result <strong>in</strong> improvement <strong>in</strong> the general<br />

environment with<strong>in</strong> the region.<br />

Development <strong>of</strong> secured landfill facility for disposal <strong>of</strong> hazardous wastes will<br />

<strong>in</strong>volve many activities as described <strong>in</strong> the report. This will <strong>in</strong>crease the<br />

opportunities <strong>of</strong> employment for the local people, which is a positive aspect <strong>of</strong><br />

the project.<br />

Cont<strong>in</strong>uous monitor<strong>in</strong>g <strong>of</strong> ground water and ambient air dur<strong>in</strong>g operation and<br />

closure <strong>of</strong> landfill facility is recommended to be carried out <strong>in</strong> the surround<strong>in</strong>g<br />

area <strong>of</strong> the facility. This will cont<strong>in</strong>ue for 30 years even after the closure <strong>of</strong> the<br />

facility.<br />

Environment Division, National Productivity Council, New Delhi<br />