Rapid <strong>EIA</strong> <strong>Studies</strong> <strong>of</strong> 3 <strong>Pre</strong>-identified <strong>Hazardous</strong> <strong>Waste</strong> <strong>Disposal</strong> <strong>Sites</strong> <strong>in</strong> NCT - Delhi:<br />

Page No.99<br />

Noise level was found to be well with<strong>in</strong> the stipulated standards for <strong>in</strong>dustrial as well<br />

as residential areas.<br />

Site –II (Wazirpur CETP Site)<br />

The ambient air quality and noise level was monitored at the site on 24 hourly basis<br />

cont<strong>in</strong>uosly for 3 days. Photo plate 16 shows the ambient air monitor<strong>in</strong>g set up at the<br />

proposed site. The results <strong>of</strong> ambient air quality and noise monitor<strong>in</strong>g at the site are<br />

given <strong>in</strong> Table 4.22 & 4.23<br />

Table 4.22: Ambient Air Quality <strong>of</strong> Wazirpur CETP Site<br />

Date Time period Sox ,<br />

ug /m 3<br />

SOx,<br />

24-hr<br />

avg<br />

NOx , ug<br />

/m3<br />

NOx, 24-hr<br />

avg<br />

4/3/02 0600 - 1400 12.30 27 55.40 56 582<br />

1400 - 2200 40.20 48.20<br />

2200 - 0600 29.40 63.30<br />

5/3/02 0600 - 1400 14.50 29 49.71 53 322<br />

1400 - 2200 42.00 50.00<br />

2200 - 0600 31.00 60.00<br />

SPM, ug/m3<br />

(24 - hr avg.)<br />

6/3/02 0600 - 1400 10.60 25 40.30 51 382<br />

1400 - 2200 35.00 56.30<br />

2200 - 0600 30.10 55.10<br />

Table 4.23: Noise level at Wazirpur CETP site<br />

Time Observed Leq, dB(A) Limits <strong>in</strong><br />

Commercial<br />

Area<br />

Day (0600 - 2100) 58 65<br />

Night (2100 - 0600) 57 55<br />

Site –III (Guman Hera Site)<br />

The ambient air quality and noise level was monitored at the site on 24 hourly basis<br />

cont<strong>in</strong>uosly for 3 days. Photo plate 17 shows the ambient air monitor<strong>in</strong>g set up at the<br />

proposed site. The results <strong>of</strong> ambient air quality and noise monitor<strong>in</strong>g at the site are<br />

given <strong>in</strong> Table 4.24 & 4.25<br />

Table 4.24: Ambient Air Quality <strong>of</strong> Guman Hera Site<br />

Date Time period SOx , ug /m 3 Sox, (24-<br />

hr avg.)<br />

NOx , ug<br />

/m3<br />

NOx, 24-<br />

hr avg<br />

SPM, ug/m3<br />

(24 - hr avg)<br />

19/3/2002 0700 - 1500 1.66 1.8 2.61 2.1 152.7931<br />

1500 - 2300 2.68 1.52<br />

2300 - 0700 1.07 2.12<br />

20/3/2002 0700 - 1500 1.08 1.7 1.84 1.6 160.23<br />

1500 - 2300 2.79 1.91<br />

Environment Division, National Productivity Council, New Delhi<br />