Rapid EIA Studies of 3 Pre-identified Hazardous Waste Disposal Sites in NCT - Delhi: Table 4.19: Ambient Air Quality around Site I & Site IV Page No.98 Station SPM, µg/m 3 Sox, µg/m 3 NOx, µg/m 3 Min Max Avg Min Max Avg Min Max Avg Bawana 129 532 322 13.4 30.5 20.8 37 49.7 42.9 Narela 121 371 221 6.8 28.4 16 15.1 44.8 33.6 Ghoga 157 421 315 6.8 16.8 10.7 6.8 38.4 20.3 Holambikalan 126 428 237 6.8 14.8 10.7 7.5 26.4 18.3 Source: Project titled REIA of proposed new Indl. Areas in Delhi, by CES for DSIDC. Primary Data Site –I : Bawana industry relocation site The ambient air quality and noise level was monitored at the site on 24 hourly basis continuosly for 3 days. Photo plate 15 shows the ambient air monitoring set up at the proposed site. The results of ambient air quality and noise monitoring at the site are given in Table 4.20 & 4.21 Table 4.20 : Ambient Air Quality Monitoring Results at Bawana Industry Relocation Site Date Time period Sox , ug /m 3 06/02/02 - 07/02/02 07/02/02 - 08/02/02 08/02/02 - 09/02/02 SOx, (24-hr avg.) NOx , ug /m 3 NOx, (24- hr avg.) *SPM, ug/m 3 (24 - hr avg.) 1400 - 2200 7.6 8 69 59 1000 2200 - 0600 7.3 55 0600 - 1400 8.7 54 1400 - 2200 8.2 7.7 38 42 600 2200 - 0600 7.1 50 0600 - 1400 7.9 39 1400 - 2200 6.1 6 40 34 400 2200 - 0600 5.5 32 0600 - 1400 6 29 The high SPM concentration is due to the presence of a rice mill adjacent to the proposed site in Bawana industry relocation site. The SOx and NOx concentration is well within the prescribed standards. Table 4.21: Noise level monitored near proposed site in Bawana Time Observed Leq, Limits in residential Limits in Industrial dB(A) area area Day (0600 - 2100) 52 55 75 Night (2100 - 0600) 40 45 70 Environment Division, National Productivity Council, New Delhi 4

Rapid EIA Studies of 3 Pre-identified Hazardous Waste Disposal Sites in NCT - Delhi: Page No.99 Noise level was found to be well within the stipulated standards for industrial as well as residential areas. Site –II (Wazirpur CETP Site) The ambient air quality and noise level was monitored at the site on 24 hourly basis continuosly for 3 days. Photo plate 16 shows the ambient air monitoring set up at the proposed site. The results of ambient air quality and noise monitoring at the site are given in Table 4.22 & 4.23 Table 4.22: Ambient Air Quality of Wazirpur CETP Site Date Time period Sox , ug /m 3 SOx, 24-hr avg NOx , ug /m3 NOx, 24-hr avg 4/3/02 0600 - 1400 12.30 27 55.40 56 582 1400 - 2200 40.20 48.20 2200 - 0600 29.40 63.30 5/3/02 0600 - 1400 14.50 29 49.71 53 322 1400 - 2200 42.00 50.00 2200 - 0600 31.00 60.00 SPM, ug/m3 (24 - hr avg.) 6/3/02 0600 - 1400 10.60 25 40.30 51 382 1400 - 2200 35.00 56.30 2200 - 0600 30.10 55.10 Table 4.23: Noise level at Wazirpur CETP site Time Observed Leq, dB(A) Limits in Commercial Area Day (0600 - 2100) 58 65 Night (2100 - 0600) 57 55 Site –III (Guman Hera Site) The ambient air quality and noise level was monitored at the site on 24 hourly basis continuosly for 3 days. Photo plate 17 shows the ambient air monitoring set up at the proposed site. The results of ambient air quality and noise monitoring at the site are given in Table 4.24 & 4.25 Table 4.24: Ambient Air Quality of Guman Hera Site Date Time period SOx , ug /m 3 Sox, (24- hr avg.) NOx , ug /m3 NOx, 24- hr avg SPM, ug/m3 (24 - hr avg) 19/3/2002 0700 - 1500 1.66 1.8 2.61 2.1 152.7931 1500 - 2300 2.68 1.52 2300 - 0700 1.07 2.12 20/3/2002 0700 - 1500 1.08 1.7 1.84 1.6 160.23 1500 - 2300 2.79 1.91 Environment Division, National Productivity Council, New Delhi 4

Rapid <strong>EIA</strong> <strong>Studies</strong> <strong>of</strong> 3 <strong>Pre</strong>-identified <strong>Hazardous</strong> <strong>Waste</strong> <strong>Disposal</strong> <strong>Sites</strong> <strong>in</strong> NCT - Delhi:<br />

Table 4.19: Ambient Air Quality around Site I & Site IV<br />

Page No.98<br />

Station SPM, µg/m 3<br />

Sox, µg/m 3<br />

NOx, µg/m 3<br />

M<strong>in</strong> Max Avg M<strong>in</strong> Max Avg M<strong>in</strong> Max Avg<br />

Bawana 129 532 322 13.4 30.5 20.8 37 49.7 42.9<br />

Narela 121 371 221 6.8 28.4 16 15.1 44.8 33.6<br />

Ghoga 157 421 315 6.8 16.8 10.7 6.8 38.4 20.3<br />

Holambikalan 126 428 237 6.8 14.8 10.7 7.5 26.4 18.3<br />

Source: Project titled R<strong>EIA</strong> <strong>of</strong> proposed new Indl. Areas <strong>in</strong> Delhi, by CES for DSIDC.<br />

Primary Data<br />

Site –I : Bawana <strong>in</strong>dustry relocation site<br />

The ambient air quality and noise level was monitored at the site on 24 hourly basis<br />

cont<strong>in</strong>uosly for 3 days. Photo plate 15 shows the ambient air monitor<strong>in</strong>g set up at<br />

the proposed site. The results <strong>of</strong> ambient air quality and noise monitor<strong>in</strong>g at the site<br />

are given <strong>in</strong> Table 4.20 & 4.21<br />

Table 4.20 : Ambient Air Quality Monitor<strong>in</strong>g Results at Bawana Industry<br />

Relocation Site<br />

Date Time period Sox ,<br />

ug /m 3<br />

06/02/02<br />

-<br />

07/02/02<br />

07/02/02<br />

-<br />

08/02/02<br />

08/02/02<br />

-<br />

09/02/02<br />

SOx,<br />

(24-hr<br />

avg.)<br />

NOx ,<br />

ug /m 3 NOx, (24-<br />

hr avg.)<br />

*SPM, ug/m 3<br />

(24 - hr avg.)<br />

1400 - 2200 7.6 8 69 59 1000<br />

2200 - 0600 7.3 55<br />

0600 - 1400 8.7 54<br />

1400 - 2200 8.2 7.7 38 42 600<br />

2200 - 0600 7.1 50<br />

0600 - 1400 7.9 39<br />

1400 - 2200 6.1 6 40 34 400<br />

2200 - 0600 5.5 32<br />

0600 - 1400 6 29<br />

The high SPM concentration is due to the presence <strong>of</strong> a rice mill adjacent to the<br />

proposed site <strong>in</strong> Bawana <strong>in</strong>dustry relocation site. The SOx and NOx concentration is<br />

well with<strong>in</strong> the prescribed standards.<br />

Table 4.21: Noise level monitored near proposed site <strong>in</strong> Bawana<br />

Time Observed Leq, Limits <strong>in</strong> residential Limits <strong>in</strong> Industrial<br />

dB(A)<br />

area<br />

area<br />

Day (0600 - 2100) 52 55 75<br />

Night (2100 - 0600) 40 45 70<br />

Environment Division, National Productivity Council, New Delhi<br />