Walter Finkbeiner GmbH, Alte Poststrasse 9 / 11, D - 72250 Freudenstadt<br />

OPERATOR’S MANUAL FOR MOBILE COLUMN LIFT TYPE EHB<br />

ELECTRICAL CONNECTION<br />

NOTE: The lift may only be connected with a appropriate power supply outlet which is<br />

installed as prescribed and earthed as per local safety regulations and which is<br />

incorporated in a protective circuit. Electrical connections have to be done by an expert.<br />

1. Connect interconnect cables from column to column, in a circuit around the vehicle.<br />

See fig.3. Lock each socket with the plug locks provided. Plug power cord on master<br />

column into the appropriate power supply outlet.<br />

2. Before operating the lift it should be checked for functionality first, without load. When<br />

operating the lift, regard the Detailed Operation Instruction enclosed.<br />

3. If lift does not begin to raise after 10 seconds of depressing the UP button, you need to<br />

stop and check motor rotation. Clockwise rotation of motor is required. Rotation of the<br />

motor can be changed. Disconnect the power cord from the power supply outlet.<br />

Remove the plug on power cord and rewire the plug by changing two phases (L1/L2).<br />

NOTE: Do not change the wiring within the lift system or control panel. The motor<br />

rotation may be different if the lift is operated at a different location.<br />

CONNECTING OF COLUMNS<br />

Master Column<br />

(can be positioned at any convenient location)<br />

Master Column<br />

(can be positioned at any convenient location)<br />

fig.3<br />

page 4