Walter Finkbeiner GmbH, Alte Poststrasse 9 / 11, D - 72250 Freudenstadt<br />
OPERATOR’S MANUAL FOR MOBILE COLUMN LIFT TYPE EHB<br />
ELECTRICAL CONNECTION<br />
NOTE: The lift may only be connected with a appropriate power supply outlet which is<br />
installed as prescribed and earthed as per local safety regulations and which is<br />
incorporated in a protective circuit. Electrical connections have to be done by an expert.<br />
1. Connect interconnect cables from column to column, in a circuit around the vehicle.<br />
See fig.3. Lock each socket with the plug locks provided. Plug power cord on master<br />
column into the appropriate power supply outlet.<br />
2. Before operating the lift it should be checked for functionality first, without load. When<br />
operating the lift, regard the Detailed Operation Instruction enclosed.<br />
3. If lift does not begin to raise after 10 seconds of depressing the UP button, you need to<br />
stop and check motor rotation. Clockwise rotation of motor is required. Rotation of the<br />
motor can be changed. Disconnect the power cord from the power supply outlet.<br />
Remove the plug on power cord and rewire the plug by changing two phases (L1/L2).<br />
NOTE: Do not change the wiring within the lift system or control panel. The motor<br />
rotation may be different if the lift is operated at a different location.<br />
CONNECTING OF COLUMNS<br />
Master Column<br />
(can be positioned at any convenient location)<br />
Master Column<br />
(can be positioned at any convenient location)<br />
fig.3<br />