RHA - Ferroli
RHA - Ferroli
RHA - Ferroli
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
GENERAL SPECIFICATIONS - Version with Desuperheater (VD)<br />
IP HEAT PUMP UNIT<br />
Acoustic Version: AB (Standard Unit)<br />
Recovery heat exchanger specifications<br />
MODEL 350.5 390.6 440.6 490.6 560.6 630.6 UM<br />
Type of recovery exchanger Brazed plates -<br />
Quantity 1 N°<br />
Max. operating pressure on wet side 600 kPa<br />
Total water content of recovery exchangers 1.3 1.3 1.3 1.3 1.3 1.3 l<br />
Unit specification<br />
Cooling capacity VD(1) 355 379 443 499 562 632 kW<br />
Power input compressor VD (1) 101 109 126 145 161 183 kW<br />
Total power input VD (1) 115 123 144 163 183 205 kW<br />
EER VD (1) 3.09 3.08 3.08 3.06 3.07 3.08 -<br />
Water flow rate VD (1) 16.9 18.1 21.2 23.9 26.8 30.2 l/s<br />
Water pressure drop VD (1) 52 55 58 62 59 57 kPa<br />
Recovered heating capacity (1) 85.2 90.7 106 120 135 152 kW<br />
Recovered water flow rate (1) 4.07 4.33 5.06 5.73 6.45 7.26 l/s<br />
Recovered water pressure drop (1) 23 26 24 30 29 36 kPa<br />
(1): The data refer to: Water temperature: evaporator inlet :12°C - evaporator outlet: 7°C, Outdoor air temperature 35°C.<br />
The data refer to: Water temperature: recovery inlet :40°C - recovery outlet: 45°C.<br />
NOTE : The HEATING CAPACITY recovered by the desuperheater exclusively refers to units<br />
operating in the cooling mode.<br />
Acoustic Version: AS (Low noise Unit)<br />
Recovery heat exchanger specifications<br />
MODEL 350.5 390.6 440.6 490.6 560.6 630.6 UM<br />
Type of recovery exchanger Brazed plates -<br />
Quantity 1 N°<br />
Max. operating pressure on wet side 600 kPa<br />
Total water content of recovery exchangers 3.8 3.8 3.8 3.8 3.8 3.8 l<br />
Unit specification<br />
Cooling capacity VD(1) 340 363 425 479 539 607 kW<br />
Power input compressor VD (1) 109 117 136 156 174 198 kW<br />
Total power input VD (1) 123 132 154 174 195 219 kW<br />
EER VD (1) 2.76 2.75 2.76 2.75 2.76 2.77 -<br />
Water flow rate VD (1) 16.2 17.3 20.3 22.9 25.7 29.0 l/s<br />
Water pressure drop VD (1) 48 50 54 57 54 53 kPa<br />
Recovered heating capacity (1) 85.2 90.7 107 120 135 152 kW<br />
Recovered water flow rate (1) 4.07 4.33 5.09 5.72 6.45 7.25 l/s<br />
Recovered water pressure drop (1) 23 26 24 30 29 36 kPa<br />
(1): Dati riferiti a: Temperatura acqua: ingresso evaporatore :12°C - uscita evaporatore: 7°C, Temperatura aria esterna 35°C.<br />
Dati riferiti a: Temperatura acqua: ingresso recupero:40°C - uscita recupero: 45°C.<br />
NOTE : The HEATING CAPACITY recovered by the desuperheater exclusively refers to units<br />
operating in the cooling mode.<br />
Acoustic Version: AX (Extra low noise Unit)<br />
Recovery heat exchanger specifications<br />
MODEL 350.5 390.6 440.6 490.6 560.6 630.6 UM<br />
Type of recovery exchanger Brazed plates -<br />
Quantity 1 N°<br />
Max. operating pressure on wet side 600 kPa<br />
Total water content of recovery exchangers 3.8 3.8 3.8 3.8 3.8 3.8 l<br />
Unit specification<br />
Cooling capacity VD(1) 334 356 416 469 528 595 kW<br />
Power input compressor VD (1) 112 120 140 160 178 204 kW<br />
Total power input VD (1) 126 135 158 178 200 225 kW<br />
EER VD (1) 2.65 2.64 2.63 2.63 2.64 2.64 -<br />
Water flow rate VD (1) 16.0 17.0 19.9 22.4 25.2 28.4 l/s<br />
Water pressure drop VD (1) 47 48 51 54 52 51 kPa<br />
Recovered heating capacity (1) 85.2 90.7 106 120 135 152 kW<br />
Recovered water flow rate (1) 4.07 4.33 5.06 5.73 6.45 7.26 l/s<br />
Recovered water pressure drop (1) 23 26 24 30 29 36 kPa<br />
(1): The data refer to: Water temperature: evaporator inlet :12°C - evaporator outlet: 7°C, Outdoor air temperature 35°C.<br />
The data refer to: Water temperature: recovery inlet :40°C - recovery outlet: 45°C.<br />
NOTE : The HEATING CAPACITY recovered by the desuperheater exclusively refers to units<br />
operating in the cooling mode.<br />
29