DC or AC Valve Solenoid in Explosion-protected ... - Magnet-Schultz
DC or AC Valve Solenoid in Explosion-protected ... - Magnet-Schultz
DC or AC Valve Solenoid in Explosion-protected ... - Magnet-Schultz
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SPECIAlIST FOR ElECTROMAGNETIC <strong>AC</strong>TUATORS AND SENSORS<br />
G BR E 2nd <strong>DC</strong> <strong>or</strong> <strong>AC</strong> <strong>Valve</strong> <strong>Solenoid</strong><br />
<strong>in</strong> <strong>Explosion</strong>-<strong>protected</strong> Design<br />
ATEX<br />
Supplement<br />
� Acc<strong>or</strong>d<strong>in</strong>g to DIN VDE 0580<br />
� Armature space pressure-tight up to max. 50 bar<br />
static pressure nom<strong>in</strong>al w<strong>or</strong>k<strong>in</strong>g pressure 5 bar<br />
� Armature with spr<strong>in</strong>g-supp<strong>or</strong>ted seal<strong>in</strong>g nipples at both ends<br />
� Exciter coil c<strong>or</strong>responds to <strong>in</strong>sulation class F,<br />
it is moulded <strong>in</strong>to a metal hous<strong>in</strong>g<br />
� Electrical connection and protection class<br />
with duly executed <strong>in</strong>stallation:<br />
� Access l<strong>in</strong>e H 05 GG-F 3 G 0.75 mm²<br />
� Protection class<br />
II 2G Ex mb II T5 - II 2D Ex tD A21 IP65 T95°C<br />
� Fasten<strong>in</strong>g with central thread <strong>or</strong> flange with 4 screws<br />
� Seal<strong>in</strong>g between solenoid and valve with o-r<strong>in</strong>g<br />
� Easy exchange of the magnetic body without<br />
open<strong>in</strong>g the pneumatic circuit<br />
� Special designs on request<br />
� Application examples:<br />
Actuation of 2/2- and 3/2-way-seat-valves,<br />
especially f<strong>or</strong> pneumatic application and other<br />
gasif<strong>or</strong>m and fluid neutral media<br />
QUALITY SINCE 1912<br />
3<br />
Product group<br />
Fig. 1 Type G BR E 022 AMX B01<br />
<strong>Magnet</strong>-<strong>Schultz</strong> GmbH & Co. KG • Postfach 1665 • D 87686 Memm<strong>in</strong>gen • Allgäuer Straße 30 • D 87700 Memm<strong>in</strong>gen<br />
Telefon ++49 (0) 8331 10 40 • Telefax ++49 (0) 8331 10 43 33 • <strong>in</strong>fo@<strong>Magnet</strong>-<strong>Schultz</strong>.de • www.<strong>Magnet</strong>-<strong>Schultz</strong>.com
QUALITY SINCE 1912<br />
Technical Data<br />
G BR E 022 AMX B01 - B03 B11 - B13<br />
Operat<strong>in</strong>g mode S1 (100 %)<br />
Rated <strong>DC</strong> (W) 4,5 -<br />
power P20 <strong>AC</strong> (VA) - 4,4<br />
Stroke s (mm) 0,5<br />
Reference temperature (°C) 40<br />
<strong>Magnet</strong>ic f<strong>or</strong>ce FM stroke 0 mm (N) 16<br />
without spr<strong>in</strong>g stroke s mm (N) 2,6<br />
<strong>Solenoid</strong> weight mM (kg) 0,17<br />
Armature weight mA (kg) 0,005<br />
Rated voltage 24 V<strong>DC</strong>, resp. 230 V/ 50 Hz, the exciter coil can<br />
be adjusted to a rated voltage of maximum 215 V<strong>DC</strong> resp.<br />
240 V/50 Hz on request.<br />
The f<strong>or</strong>ce values <strong>in</strong>dicated <strong>in</strong> the tables refer to 90 % of the rated<br />
voltage UN = 24 V resp. 220 V/50 Hz without spr<strong>in</strong>g and to the<br />
n<strong>or</strong>mal operat<strong>in</strong>g temperature.<br />
F<strong>or</strong> other rated voltages deviations of magnetic f<strong>or</strong>ce may occur.<br />
Due to natural dispersion to f<strong>or</strong>ce values may deviate by ± 10 %<br />
from the values <strong>in</strong>dicated <strong>in</strong> the tables.<br />
The n<strong>or</strong>mal operat<strong>in</strong>g temperature is based on:<br />
a) Mount<strong>in</strong>g on heat-<strong>in</strong>sulat<strong>in</strong>g base<br />
b) Rated voltage: <strong>DC</strong> 24 V, <strong>AC</strong> 230 V/50 Hz (other voltages<br />
on request)<br />
c) Operat<strong>in</strong>g mode S1 (100 % ED)<br />
d) Reference temperature 40° C<br />
The response times and the maximum operat<strong>in</strong>g frequency are<br />
not <strong>in</strong>dicated, because they depend on the respective application<br />
case and pressure.<br />
We recommend us<strong>in</strong>g compressed air c<strong>or</strong>respond<strong>in</strong>g to DIN<br />
ISO 8573/1, class 3. Elastomer neutral oils should be used f<strong>or</strong><br />
lubricat<strong>in</strong>g the compressed air, otherwise we ask you to please<br />
contact the manufacturer.<br />
This part list is a document f<strong>or</strong> technically qualified personnel.<br />
The present publication is f<strong>or</strong> <strong>in</strong>f<strong>or</strong>mational purposes only and<br />
shall not been construed as mandat<strong>or</strong>y illustration of the products<br />
unless otherwise confirmed expressively.<br />
Please make sure that the described devices are suitable f<strong>or</strong><br />
your application. Supplementary <strong>in</strong>f<strong>or</strong>mation concern<strong>in</strong>g its<br />
duly assembly can be found also <strong>in</strong> -Technical Explanations,<br />
<strong>in</strong> the effective DIN VDE0580 as well as <strong>in</strong> the relevant<br />
specifications.<br />
2<br />
The edition of the present pamphlet cancels the f<strong>or</strong>mer ones.<br />
pressure (bar) = f (NW) mm ø<br />
serial design<br />
Fig. 2 Switchable pressure as function of the nom<strong>in</strong>al width of the valve<br />
seat f<strong>or</strong> type G BR E 022<br />
<strong>Valve</strong> Construction<br />
The valve construction shall be executed acc<strong>or</strong>d<strong>in</strong>g to figure 3. A<br />
valve seat with most possible rectangularity to the armature axis<br />
and conical profile with a smooth surface ensure a maximum<br />
perf<strong>or</strong>mance and service life of the solenoid valve.<br />
Fig. 3 <strong>Valve</strong> f<strong>or</strong> type GBRE 022 AMX B01 and B11<br />
valve seat<br />
Size of b<strong>or</strong>e hole<br />
depend<strong>in</strong>g<br />
on nom<strong>in</strong>al width<br />
Inf<strong>or</strong>mation and remarks concern<strong>in</strong>g European directives<br />
can be taken from the c<strong>or</strong>respondent <strong>in</strong>f<strong>or</strong>mation sheet which is<br />
available under Produkt<strong>in</strong>fo.<strong>Magnet</strong>-<strong>Schultz</strong>.com.<br />
Note on the RoHS guidel<strong>in</strong>e 2002/95/ EC<br />
Acc<strong>or</strong>d<strong>in</strong>g to our current state of knowledge the devices pictured <strong>in</strong><br />
this document do not conta<strong>in</strong> any substances <strong>in</strong> concentration values<br />
<strong>or</strong> applications f<strong>or</strong> which putt<strong>in</strong>g <strong>in</strong>to circulation with products<br />
manufactured from them is prohibited <strong>in</strong> acc<strong>or</strong>dance to RoHS.
Constructive data<br />
Fig. 4 Type GBRE 022 AMX B01 (<strong>DC</strong>)<br />
GBRE 022 AMX B02 (<strong>DC</strong>)<br />
GBRE 022 AMX B03 (<strong>DC</strong>)<br />
Type GBRE 022 AMX B11 (<strong>AC</strong>)<br />
GBRE 022 AMX B12 (<strong>AC</strong>)<br />
GBRE 022 AMX B13 (<strong>AC</strong>)<br />
t<strong>or</strong>que 150 Ncm max.<br />
Ex stamp impr<strong>in</strong>ted on rat<strong>in</strong>g plate<br />
approx.<br />
protective conduct<strong>or</strong><br />
connection<br />
standard length 1000<br />
(special lengths as<br />
per <strong>or</strong>der)<br />
heat-resistant rubber hose<br />
type H 05 GG - F 3 G 0,75<br />
mm²<br />
Illustrations without guarantee – modifications and supply availability reserved.<br />
Type GBRE 022 AMX B03 and<br />
GBRE 022 AMX B13<br />
QUALITY SINCE 1912<br />
3
QUALITY SINCE 1912<br />
Application example and switch<strong>in</strong>g function<br />
Fig. 5 Type GBRE 022 AMX B01 (<strong>DC</strong>), Type GBRE 022 AMX B22 (<strong>AC</strong>)<br />
f<strong>or</strong> 3/2-way valve, de-energized locked<br />
Fig. 7 Type GBRE 022 AMX B03 (<strong>DC</strong>), Type GBRE 022 AMX B13 (<strong>AC</strong>)<br />
f<strong>or</strong> 2/2-way valve<br />
Type code<br />
Device group<br />
Series<br />
Modifications<br />
Size <strong>in</strong> the series<br />
Execution <strong>in</strong> the series<br />
Protection code<br />
Design number<br />
G BR E 022 A MX B01<br />
Special designs<br />
We are pleased to solve application-<strong>or</strong>iented problems. A<br />
reliable solution can be found out, if you put at our disposal<br />
detailed <strong>in</strong>f<strong>or</strong>mation about the application conditions<br />
<strong>in</strong> acc<strong>or</strong>dance with the - Technical Explanations.<br />
Please don´t hesitate to contact our responsible technical<br />
office to receive supp<strong>or</strong>t.<br />
Fig. 6 Type GBRE 022 AMX B02 (<strong>DC</strong>), Type GBRE 022 AMX B12 (<strong>AC</strong>)<br />
f<strong>or</strong> 3/2-way valve, de-energized unlocked<br />
Order example<br />
Subject to general conditions. F<strong>or</strong> the supply of products and services. Of the electical and electronics <strong>in</strong>dustry and sales terms.<br />
4 Pr<strong>in</strong>ted <strong>in</strong> Germany 032012/04 Alt<br />
<strong>DC</strong><br />
Type G BR E 022 AMX B01<br />
Voltage 24 V <strong>DC</strong><br />
Operat<strong>in</strong>g mode S1 (100 %)<br />
<strong>AC</strong><br />
Type G BR E 022 AMX B11<br />
Voltage 230 V / 50 Hz<br />
Operat<strong>in</strong>g mode S1 (100 %)