<strong>Manual</strong> – Digital locking cylinder 3061<br />

Page 13<br />

3.7 No acoustic confirmation signals<br />

This checkbox should be activated if you want to suppress the acoustic confirmation<br />

signal for programming from the locking cylinder.<br />

This function is especially practical for network-based programming or data reading, as<br />

the acoustic signal emitted by the locking cylinder is not usually audible due to the<br />

distance.<br />

3.8 Logging unauthorised access attempts<br />

As a rule, the system only logs authorised transponder operations. You will need to<br />

select this option if you wish to log attempts to open the door using an unauthorised<br />

transponder.<br />

Unauthorised access attempts include:<br />

• Access attempts without authorisation<br />

• Access attempts outside of the authorised time zone<br />

• Access attempts under activated alarm system and simultaneous use<br />

of a <strong>SimonsVoss</strong> shunt lock.<br />

As a general rule the system only logs transponders belonging to the same<br />

locking system, i.e. they must have the same locking system ID (SID).<br />

3.9 Time-switch function<br />

This is only possible with the .ZK version. The time-switch function requires a time<br />

zone plan to be loaded which then activates (engages) the locking cylinder during the<br />

specified times (in Group 5 - Locking). A door can be freely accessible by turning the<br />

knob during the day, but only accessible by means of transponder during the night.<br />

Caution: The lock does not engage automatically when the knob is disengaged.<br />

The following options are available in the field "Time-controlled activation" when the<br />

time-switch function is selected:<br />

1. <strong>Manual</strong> disengage<br />

The locking cylinder does not disengage automatically at the appointed time but<br />

remains engaged until a subsequent command is received from an authorised<br />

transponder.<br />

2. Automatic disengage (default setting)<br />

The locking cylinder disengages automatically at the time appointed in the time<br />

zone plan.