Caption<br />

Page 2<br />

Explanation of technical terms<br />

Access logging<br />

Activation transponder<br />

Activation unit<br />

Central node<br />

Deactivation unit<br />

Higher priority<br />

locking level<br />

Locking<br />

LockNode<br />

Network<br />

Overlay mode<br />

Additional function of the digital components in the TC version:<br />

The digital lockings store the last 128 accesses with<br />

date, time of day and user name. The stored accesses can<br />

be read out with the help of the Config-Device or PalmCD2 or<br />

over the network.<br />

Can be inserted within the scope of the shunt lock function,<br />

so that, in case of an emergency, the deactivation of the<br />

lockings can be released when the alarm system is activated.<br />

The door can then be opened with an authorised transponder.<br />

See shunt lock function<br />

Component of the network installation: is connected to the PC<br />

using the RS232 interface and represents the central unit of<br />

the network.<br />

See shunt lock function<br />

If a transponder should lock in more than three different<br />

locking systems, one sets up a higher priority transponder.<br />

General term for digital locking cylinders, digital Smart Relays<br />

and shunt lock components.<br />

Component of the network installation: LockNodes are installed<br />

in the vicinity of a digital locking and are connected to<br />

the CentralNode over the network wiring. The data transmission<br />

from the LockNode to the digital locking takes place over<br />

radio without wires. Using the locking plan software, the<br />

lockings can be programmed or read out.<br />

All digital components can be connected to a network and<br />

configured and administered from a central PC. A physical<br />

approach to the lockings with the SmartCD is then no longer<br />

necessary.<br />

Locking systems with up to 1000 transponders can be operated<br />

in the so-called overlay mode. If a transponder should<br />

be lost in this case, you simply set up a replacement transponder<br />

in the locking plan and program it. Then go to all<br />

lockings to which this transponder has authorisation. After the<br />

activation of the transponder, the locking recognises that this<br />

is a replacement transponder. The old, lost transponder is<br />

automatically blocked.