LON – Network 3065<br />

Page 28<br />

- What is an LPI-10 Compact?<br />

An LPI-10 Compact essentially corresponds to the LPI-10, but with the difference that<br />

the LPI-10 Compact is always designed for 62 LockNodes and does not need a<br />

separate plug-in power supply. It is connected directly to the 230V~ at the customer.<br />

- How many LPI-10 or LPI-10 Compact modules are needed?<br />

At least one LPI-10 or LPI-10 Compact must be used for each segment (divided by<br />

routers). The number depends on the particular segment structure. In principle,<br />

however, it can be said that each LockNode in the segment must be supplied with at<br />

least 35 V DC in order to guarantee perfect operation.<br />

- Where should the LPI-10 or LPI-10 Compact be placed in the segment?<br />

At least one LPI-10 or LPI-10 Compact must be used for each segment (divided by<br />

routers). The position of the LPI-10 or LPI-10 Compact depends on the particular<br />

segment structure. In principle, however, it can be said that placement in the middle<br />

of the segment is the most sensible.<br />

If you have other questions, please contact your trade partner or the manufacturer.