LON – Network 3065<br />

Page 21<br />

9.0 Network Cable<br />

9.1 General Information<br />

Every LockNode is networked with one line consisting of two twisted wires (twisted<br />

pair). The data and the supply voltage are both transmitted over this line (see Fig. on<br />

page N2 or N3). An LPI-10 or LPI-10 Compact module feeds the twisted pair line with<br />

voltage (approximately 48 V DC).<br />

9.2 Cable Laying<br />

There are almost no restrictions placed on the cable laying when the given cable<br />

types are used. As a matter of principle, however, placement parallel to cables with<br />

strongly pulsating high voltage should be avoided. If, however, due to structural<br />

reasons, it is possible to use only cable that has already been laid but which either<br />

does not meet the required demands or which meets them only partially, the result<br />

can be interference due to radiation from other cables or systems. This interference<br />

can affect the performance capability of the network or can even lead to a complete<br />

network blackout. Therefore, it is important in these cases to pay special attention to<br />

cables or external systems that are in the vicinity of the transmission cable. This<br />

means high power machine systems, elevators, microwave systems, or transmission<br />

systems, for example.<br />

<br />

Connect the shields of all network cables to one another. Normally, these are<br />

connected to the potential compensation on the LPI-10.<br />

9.3 Cable Types<br />

The type cable that you use depends on the following factors:<br />

1. Total cable length (from the CentralNode to the last LockNode)<br />

2. Cable length between the LockNodes<br />

3. Network topology: wiring plan (star or bus system)<br />

With no topology With no topology Bus topology with<br />

terminators<br />

Total length<br />

Distance between Total length<br />

nodes<br />

JY (ST) Y 2x2x0.8 500 m 320 m 900 m<br />

Category 5 450 m 250 m 900 m