LON – Network 3065<br />

Page 8<br />

3.0 Central Node<br />

3.1 Method of Operation<br />

The CentralNode produces the interface between the PC and the network. One<br />

CentralNode is needed per network.<br />

☺<br />

To use a CentralNode in combination with LSM, please contact your trade<br />

partner or the manufacturer.<br />

The CentralNode is connected to a free serial interface (e.g., COM1) on the PC. The<br />

ConfigDevice (or SmartCD) needed for programming transponders is connected to a<br />

different free interface on the PC (e.g., COM2). If only one interface is available, you<br />

can alternately connect the ConfigDevice (or SmartCD) and the CentralNode,<br />

depending on which you need. To do this, you must specify the device currently being<br />

used in the locking plan software. Insert the connection cable, which is delivered with<br />

the system, to the RJ-45 socket of the CentralNode.<br />

The red and blue lines on this cable are available for connection to the in-house<br />

network cable; the black line on the cable is for grounding. In order to guarantee<br />

flawless functioning of the network, the black line must be connected to the LPI-10's<br />

potential compensation. The cable's screening can be used for grounding.<br />

☺<br />

The CentralNode does not need a supply voltage. This is already provided<br />

by the LPI-10 over the network cable.