WAVENET RADIO NETWORK 3065<br />

Page 23<br />

In the LDB or LSM user interface, an open contact has a value of 0 and a closed<br />

contact has a value of 1. In the diagram above, for example, if contact 1 is used to<br />

monitor a door, an opening door will constitute an event: ‘Input1 transition from 1 to<br />

0’, if contact 1 is closed when the door is closed and open when the door is open.<br />

Internally, the output takes the form of a transistor in open-collector switching. The<br />

white and brown cables are available for connecting to external devices (e.g.<br />

buzzers). The following applies: Out = brown, ground = white.<br />

Connection example for possible output circuit: