VdS Shunt lock function 3066<br />

Page 10<br />

Test the shunt lock function again after you have connected the lock switch contact.<br />

Try to deactivate the locking cylinder or Smart Relay even when the bolts have not<br />

been driven out.<br />

• External light emitting diode<br />

You can connect an external light emitting diode to soldering terminals 3 and 4 so that<br />

you have a visual display in the outside area showing whether the cylinder or Smart<br />

Relay is activated or deactivated. Maximum length of the line: 10 m (33 feet).<br />

• Switch contacts (not used)<br />

Soldering terminals 5 to 7 are not needed for the deactivation unit.<br />

• Sabotage contacts<br />

Connect these to soldering terminals 8 to 11. Solder the Rs resistor (terminating<br />

resistor or short circuit) to soldering pins X27 and X28 (refer to the drawing).<br />

Install other deactivation units, if any, according to the same plan.<br />

2.2.3 Connecting Deactivation Request and Deactivation Acknowledgement<br />

Refer to Chapter 2.5