Smart Output Module<br />

Page 14<br />

8.4 Adjust the Pulse Length<br />

The modules appear in the locking plan as the locking type "expansion module". You<br />

can select a pulse length from 0.1 to 25.5 seconds in the configuration for each<br />

module. This length then applies to all of the module's outputs.<br />

8.5 Select Signaling<br />

Signaling is a special function where two of a module's outputs always work together.<br />

The first output reacts completely normally, depending on transponder operation; the<br />

output assigned to it simultaneously generates an alternating signal. You can select<br />

this option, for example, if you want to have the keys that are released when an<br />

elevator is controlled blink.<br />

Attention: If you select this option, the number of outputs that are switched<br />

when authorized is reduced from eight to four.<br />

Output assignments for signaling:<br />

1 5<br />

2 6<br />

3 7<br />

4 8<br />

8.6 Automatic Name Assignment in the Software<br />

The <strong>SimonsVoss</strong> software automatically assigns designation to modules when the<br />

modules are created. The following convention is used:<br />

SMART RELAY NAME - MOD0 - OUT1<br />

(z.B. Aufzug1-MOD0-OUT4)<br />

Module<br />

address:<br />

0 to F<br />

Output<br />

number:<br />

1 to 8<br />

8.7 Inverting the Outputs<br />

This option allows the output switching behavior to be inverted. If there is no supply<br />

voltage, all output relays are always closed.