Smart Output Module<br />

Page 10<br />

7.1 Standard Power Supply Connection<br />

I-|I+| B | A | C |4a|4b|3a|3b|2a|2b|1a|1b<br />

Out|<br />

|A-|K1|A+| +|K2|8a|8b|7a|7b|6a|6b|5a|5b<br />

Netzteil<br />

Power supply<br />

+<br />

-<br />

7.2 Emergency Release Connection for a Fire Alarm <strong>System</strong><br />

When the fire alarm system relay opens, the Smart Output Module supply voltage is<br />

stopped, consequently closing outputs 1 to 8.<br />

Out| I-|I+| B | A | C |4a|4b|3a|3b|2a|2b|1a|1b<br />

|A-|K1|A+| +|K2|8a|8b|7a|7b|6a|6b|5a|5b<br />

Brandmeldeanlage<br />

Fire alarm system<br />

Electric Öffner<br />

strike<br />

Netzteil Power supply<br />

+<br />

+<br />

- 12 VDC 1<br />

-<br />

Hier bitte die<br />

Please<br />

mitgelieferten<br />

insert the<br />

Brücken stecken<br />

bridges<br />

included