<strong>Manual</strong> – Digital Half Cylinder 3061<br />

Page 18<br />

6.2 Transponder<br />

When the transponder's battery voltage starts to decline, each transponder<br />

operation will cause the half cylinder to emit eight short signal tones in rapid<br />

succession after it has disengaged.<br />

7. Signal tones<br />

Signal type Meaning Required action<br />

2 short tones prior to engaging and<br />

one short tone after disengaging<br />

Normal operation<br />

None<br />

Battery warning level 1:<br />

8 short tones prior to engaging<br />

Battery warning level 2:<br />

8 short tones for 30 seconds<br />

with a one-second break between<br />

each set<br />

Batteries will soon be<br />

empty<br />

Batteries are nearly completely<br />

discharged<br />

Change the cylinder batteries<br />

Replace the cylinder batteries<br />

immediately!<br />

8 short tones after disengaging Transponder battery empty Have the transponder battery<br />

changed<br />

1 short signal tone without engaging<br />

the cylinder<br />

• Attempt to operate outside<br />

of time zone<br />

• Armed alarm system<br />

with simultaneous use of<br />

a <strong>SimonsVoss</strong> shunt<br />

lock<br />

None